background image

Y1-03-0250 Rev. B 

19 

 

5.  Installing the Optional optical GPS interface cable 

The  beacon  is  fitted  with  an 
optical  interface  to  connect  with 
an  external  Global  Positioning 
System  (GPS)  receiver  that  will 
determine 

the 

latitude 

and 

longitude of its position. 
 
The  black  lead  wire  with  white 
stripes  should  be  connected  to 
the  output  of  the  external  GPS 
receiver  positive  transmitter  pin. 
The  black  wire  should  be 
connected to the negative pin. 
 
If you have a Category I beacon and bracket, the connector is at the end of 
the  black  lead  wire  plugs  into  the  beacon  via  the  bezel  on  the  top  of  the 
beacon. See the location of the GPS interface in previous figures (“Anatomy 
of your beacon”, page 7 and “Top View”, page 8). It is important to seat the 
connector completely in the bezel for an operational connection. 
 
If  you  have  a  Category  II  beacon  and  bracket,  your  connector  has  two 
extensions on it that must be aligned with the two notches on the Category II 
beacon  bezel.  The  connector  is  then  gently  inserted  downward  into  place 
and turned 90° to lock the connector into the bezel. 
 
If  the  external  GPS  receiver  is  operational  and  the  connection  has  been 
correctly made to the optical interface, the green LED in the optical interface 
will start flashing at activation. 
 

NOTE:

 The baud rate output for your GPS receiver NMEA 0183 should be 

4800  bps.  If  you  are  not  sure  if  your  receiver  is  NMEA  0183  compliant, 
check  the  interface  settings  listed  in  your  GPS  manual.  To  optimize  your 
GPS  interface  feature,  be  sure  that  your  GPS  receiver  is  equipped  with  a 
NMEA 0183 Version 1.5 or higher with GPGGA sentence enabled. 
 
Consult  your  GPS  receiver  manual  for  the  maximum  cable  length 
acceptable  for  an  external  GPS  connection  to  the  beacon.  Also  see 
Appendix  A  for  information  regarding  the  use  and  testing  of  your  GPS 
system in conjunction with the beacon.

 

 
Using  the  optical  interface  is  not  necessary  for  the  beacon  to  function 
properly; it will, however, enhance the beacon’s performance. 

Содержание RLB-38 2874

Страница 1: ...OWNER VESSEL RADIO CALL SIGN UIN...

Страница 2: ...or use your new ACR Electronics product please read this Product Support Manual in its entirety If you have questions regarding the contents of the manual please contact our Technical Service Departme...

Страница 3: ..._____________________ 15 STEP FOUR MAINTAINING THE BEACON ___________________________ 20 APPENDIX A USING AND TESTING THE GPS SYSTEMS_________________ 25 APPENDIX B THE COSPAS SARSAT SYSTEM __________...

Страница 4: ...able to determine which country s database will have your registration information SAR forces will have information as to who you are as the owner of the beacon the name and type of vessel that you ha...

Страница 5: ...to register is online at www beaconregistration noaa gov 2 Faxing a registration is also acceptable Fax the registration form to the fax number on the top of the registration form NOTE Do not confuse...

Страница 6: ...ww 406registration com To verify that the unit is properly programmed for your country view the UIN label on the back of the unit In the event that the beacon is not programmed for your country the sa...

Страница 7: ...s message is sent to Cospas Sarsat satellites and in turn the distress message is relayed to SAR The distress message contains important information about the beacon and its owner Additional informati...

Страница 8: ...in the future Activation switch with Witness Tab The activation switch embodies a special patented method of activating a beacon Refer to a subsequent section of this manual for how to activate the b...

Страница 9: ...Y1 03 0250 Rev B 8 Top View Switch Positions Strobes Optional GPS Interface Antenna Green LED Red LED Activation Test Switch OFF READY Position TEST Position ON TRANSMITTING Position...

Страница 10: ...Bracket Category 1 SeaShelter 3 Bracket Spring Release Knob HydroFix Hydrostatic Release Unit HRU Ejector Spring Antenna Hook Front cover hook detent Optional GPS Interface Cable Antenna Hook Water S...

Страница 11: ...om the bracket Two conditions must be met for a Category II beacon to automatically activate It must be out of its bracket It must be wet NOTE Either condition by itself will not automatically activat...

Страница 12: ...longer in its bracket and when continuity is created by water between two of the top cap screws an activation circuit is completed NOTE Transmission of the 121 5 MHz and 406 MHz signals will not occur...

Страница 13: ...gory I or II beacon MANUALLY activates with the following sequence 1 Remove the beacon from its bracket 2 Activation method one Place beacon in water 3 Activation method two Lift the switch to a verti...

Страница 14: ...e the EPIRB with you if abandoning ship provided there is time to get it Tether beacon using the lanyard to the life raft and let the beacon float if in a life raft Keep EPIRB upright for best signal...

Страница 15: ...backwards in its bracket lanyard roll must face in Do not clean the beacon with a water hose and brush while out of its bracket Reporting Should there be for any reason an inadvertent activation or f...

Страница 16: ...e calendar as seen below 2 Mounting location The selection of a mounting location will vary from vessel to vessel Beacons should be protected from outside influences while being readily accessible at...

Страница 17: ...ruction to allow the beacon to automatically float free from the vessel in case of sinking The SeaShelter3 can be mounted on a vertical surface with the beacon antenna pointing skyward or a horizontal...

Страница 18: ...ss Pull the beacon with steady pressure from the bracket It is not necessary to remove the HydroFix Hydrostatic Release Unit HRU to mount the bracket using four of the holes For extreme conditions a f...

Страница 19: ...to a flat surface Remove the beacon from the bracket To do this while holding the assembly press the PUSH lever to release the beacon from the bracket Pull the beacon forward and down to remove The br...

Страница 20: ...that must be aligned with the two notches on the Category II beacon bezel The connector is then gently inserted downward into place and turned 90 to lock the connector into the bezel If the external...

Страница 21: ...be inspected for deterioration and or residue buildup that may affect the function of the beacon or automatic release Part of the visual check includes checking the antenna for tightness Clean the be...

Страница 22: ...electronics com hazmat default htm In the case of the RLB 38 the product contains small batteries that are non hazardous However regulations can change Be advised that it is best to verify the shippin...

Страница 23: ...your local authorities that the EPIRB has been lost or stolen Contact NOAA at 888 212 7283 212 SAVE or your national authority with the following information o Police department name o Police departm...

Страница 24: ...will void your warranty and may cause the bracket to malfunction Check the date of manufacture on the new HRU Follow the instructions that accompany the HydroFix for marking the next expiry date and...

Страница 25: ...n a once per month schedule Do not exceed sixty 60 Self Test cycles limit in the five year life of the battery to conserve the battery for emergency use The functional Self Test is initiated by moment...

Страница 26: ...escue Authority and may lead to a faster rescue Since the last valid GPS position data may stay in the memory for up to 4 hours the user should take care to make sure that the GPS position data stored...

Страница 27: ...are acquired the data is included in the digital message of the next 406 MHz transmission The LED blinks green when GPS coordinates are sent If a time period of 4 hours passes without the internal GPS...

Страница 28: ...oordination Center RCC The RCC dispatches Search and Rescue SAR forces The addition of the GEOSAR satellite system greatly improves the reaction time for a SAR event This satellite system has no Doppl...

Страница 29: ...TER Frequency 406 037 MHz Power output 5 W Digital message format Standard location protocol for the USA Beacon can be reprogrammed at a service center to other coded formats and to national location...

Страница 30: ...ears for the following products EPIRB PLB S VDR SSAS 2 Useful Life Policy The typical service life of a properly maintained Product is limited to 12 years from date of manufacture Products that are 12...

Страница 31: ...C Type Examination Module B Certificate No BSH 4612 5061677 10 EC Quality System Module D Certificate No BSH 4613 05102 1251 09 Regulations and IMO Resolution A 662 16 ITU R M 633 2 05 00 Standards IM...