SECTION 1 - HOW THE SEARCHLIGHT WORKS 

The  RCL-75  was  specially  designed  for  mariners  who  require  a  high 
intensity remote controlled  searchlight that  is compact, light  weight and 
can stand up to the tough marine environment. 
 
The  RCL-75  searchlight  system  contains  an  intense  light  beam  that 
produces  180,000  peak  candlepower  by  combining  two  55W  halogen 
lamps  with  unique  optical  quality,  parabolic  reflectors.  All  functions  of 
the  searchlight  can  be  electrically  operated  by  remote  control  from  the 
pilot  area  of  the  vessel  using  the  remote  control  Point  Pad™  and 
interconnecting cable supplied with the RCL-75. 
 
The  sleek,  robust  design  and  modern  construction  materials  of  the 
searchlight  body  makes  it  attractive  for  recreational  and  commercial 
vessels.  The  searchlight  is  made  of  a  UV  resistant  ASA  plastic  to 
minimize yellowing, and is gasketed and finished to repel the weather. 

 

SECTION 2 - PREPARING TO INSTALL 

Unpacking the RCL-75 

Before proceeding with the installation of the RCL-75, please verify that 
the content of the box includes the following: 

 

QTY 

ITEM 

ACR PART NUMBER 

Light assembly 

A3-06-2177 

Deck mount 

A1-18-1724 

17’ wire harness 

9426 

Remote control Point Pad™ and extra 
cover for flush mounting 

9428 

S/S Allen bolts 

A1-05-0734-1 

S/S nuts 

A1-05-0736 

S/S flat washers 

A1-05-0741 

S/S lock washers 

A1-05-0737 

Special L wrench (Allen wrench and 
Phillips head screwdriver) 

T1-04-0047 

U clamps for remote control Point Pad™ 
flush mount 

A1-17-1366 

Mounting gasket 

A1-25-0132 

Surface mount gasket 

A1-25-0135-1 

Flush mount gasket 

A1-25-0135-2 

Product Support Manual 

Y1-03-0158 

Light base mount template* 

Y1-03-0158-1 

Remote control panel template (flush)* 

Y1-03-0158-1 

Remote control panel template (surface)* 

Y1-03-0158-1 

*Templates are on a separate sheet in this box. 

 

 

Содержание RCL-75

Страница 1: ...PRODUCT SUPPORT MANUAL RCL 75 Remote Control Searchlight System Model No RCL 75 Product No 1946 Y1 03 0158 Rev H...

Страница 2: ...954 981 3333 or email at service acrelectronics com Please be ready to provide the technician with the page number you wish to discuss If you have a question that is not covered in the manual please...

Страница 3: ...__ 6 SECTION 4 OPERATION _________________________________ 10 SECTION 5 CARE AND MAINTENANCE _____________________ 10 APPENDIX A SPECIFICATIONS ____________________________ 15 APPENDIX B ACCESSORIES__...

Страница 4: ...nt ASA plastic to minimize yellowing and is gasketed and finished to repel the weather SECTION 2 PREPARING TO INSTALL Unpacking the RCL 75 Before proceeding with the installation of the RCL 75 please...

Страница 5: ...above is missing please contact ACR Electronics Technical Service by email at service acrelectronics com or by phone at 1 954 981 3333 Please be ready to provide the serial number of your unit and lo...

Страница 6: ...eration should be given to the selection of a mounting location for the RCL 75 and the Point Pad remote control panel Location helps assure maximum performance of the light Typical mounting locations...

Страница 7: ...ill need 1 4 diameter stainless steel bolts nuts and washers If the mounting area is robust enough pan head lag screws may be used If the surface area can be reached from the underside bolting with lo...

Страница 8: ...rill holes will not impact or harm other items wires plumbing hardware bulkhead The URP 102 Point Pad is supplied as a surface mount unit see figure 4 A flush mount option is provided see figure 5 To...

Страница 9: ...h is to be located i e bulkheads wires plumbing hardware Check in advance to verify the wiring harness can be routed to this location Mounting the Light Make sure area is clean and dry Decide on the u...

Страница 10: ...3 4 Put the mounting gasket on the deck mount or shaped plate if used Use caulk or bedding compound to seal bolt and wire holes before deck mount is attached to deck The plates are keyed to each other...

Страница 11: ...etergent and water if desired Rotate the light left then right and up then down periodically to keep motors and turning surfaces clean and operational WARNING DO NOT rotate the light manually This wil...

Страница 12: ...t sides of front and 4 counter sunk Phillips screws attaching top cover to lower case Use L wrench furnished with light see Figure 8 3 Carefully remove top cover by lifting straight up see Figure 9 4...

Страница 13: ...leeve with needle nose pliers and push through the partition wall see Figure 12 7 Gently remove the entire reflector assembly from the body see Figure 13 8 Place the reflector assembly face down 9 Rem...

Страница 14: ...gear toothed rack is on the right and the smooth arch is on the left The wires on the left are formed sharply down and back of the bulb assembly then a 1 inch 2 54cm diameter loop is formed back up a...

Страница 15: ...screw holes at the front match the metal braces 22 Reinstall the four 4 long cover screws starting from the back and work forward then install the two 2 top screws at each side total of 4 Tighten all...

Страница 16: ...mum with Molex quick connect locking connectors on each end Peak beam candle power 180 000 candela Lamp Dual beam 55 watt halogen Reflector size 6 x 4 5 Beam spread degrees Horizontal 8 Approx Vertica...

Страница 17: ...r operating life 9403 Base gasket 9425 2 nd station cable harness 17 5 2m length water proof connector 9426 Riser 1 inch 2 54cm Can be stacked to raise light 9427 2 nd station Point Pad control flush...

Страница 18: ...Y1 03 0158H 17 Figure 21 Installation with extension cable harness Figure 22 Installation with second Point Pad station...

Страница 19: ...ND EXPRESS OR IMPLIED AS TO MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER WITH RESPECT TO THIS PRODUCT The Company shall not be liable for consequential or special damages To pl...

Страница 20: ...N 60945 2002 Immunity IEC 61000 4 2 1995 Electrostatic Discharge IEC 61000 4 3 1995 Radiated Immunity IEC 61000 4 6 1996 Conducted Immunity Power and I O Leads IEC 61000 4 11 1994 Voltage Dips and Int...