OWL Data Logger
28
Copyright © 2010 ACR Systems Inc. All Rights Reserved.
15
1.940 VDC
31
39.00VDC
1.6.3
Specifications
Voltage Input
Ranges:
0 to 120mV, 240mV ... 1.92V
0 to 2.40V, 4.80V ... 38.4V
Max Voltage:
±40VDC
Accuracy:
±1% full scale
Resolution:
0.5% (8 bits)
Input Impedance:
> 100k ohms
Cable:
2m (6ft) length with PVC jacket to IP67 connector
Equation:
204
1.6.3.1
Choosing Transducers
A
transducer
is defined as a device that receives energy from one system and retransmits it, in
a different form, to another system. A
transmitter
is a term usually reserved for transducers in
a current loop circuit. In this section, the terms transducer and transmitter will be used
interchangeably.
For a transducer to be useful, the retransmitted signal must be compatible with standard
instrumentation. For the OWL DC Voltage logger, this is in the form of an analog DC voltage.
Many compatible transducers exist for measuring such variables as temperature, relative
humidity, pressure, speed, pH and more. You can obtain these from a wide variety of
manufacturers or distributors. An extensive listing of sensors and companies is published
yearly by
Sensors
Magazine.
To figure out what to look for when choosing transducers, it is helpful to know a few technical
terms and how they relate to use with your OWL data logger.
Excitation Voltage
This term refers to the input voltage that a transducer requires in order for it to work properly.
It is either specified as a range (for example, 9 to 30 volts DC) or a specific voltage (for
example, 10 volts DC). When a range is specified, it means you can use an unregulated
power supply (such as a battery) as long as voltages within the range are provided. Usually, if
a specific voltage is required, it means you require a regulated power supply.
When an unregulated power supply is specified for the excitation voltage, a regulated one may
also be used. The reverse, however, is not true. Millivolt pressure transducers, for example,
usually require regulated power supplies.
Содержание OWL 100
Страница 3: ...TrendReader is a Registered Trademark of ACR Systems Inc TRADEMARK NOTICES ...
Страница 4: ......
Страница 43: ...OWL Data Logger 36 Copyright 2010 ACR Systems Inc All Rights Reserved Table A 1 Temperature Ranges in Celsius ...
Страница 44: ...OWL Data Loggers 37 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Страница 45: ...OWL Data Logger 38 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Страница 46: ...OWL Data Loggers 39 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Страница 48: ...OWL Data Loggers 41 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Страница 49: ...OWL Data Logger 42 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Страница 50: ...OWL Data Loggers 43 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Страница 52: ...OWL Data Loggers 45 Copyright 2010 ACR Systems Inc All Rights Reserved 20 min 455 2 20 0 30 min 682 15 30 0 ...
Страница 54: ......
Страница 55: ......