Troubleshooting
◆
The solution for digital display code problem:
1
The digital display window
show “E1”
1. The Refrigerator chamber
Tem. Sensor is open circuit or
short circuit.
2. The Refrigerator chamber
Tem. Sensor is bad.
3. The control PCB is bad.
1. Using a Multimeter with the ohm
switch to measure the resistor of
sensor or checking the connecting is
well or not.
2. Change the sensor
3. Change the control PCB