12
7. Take out the main
board.
◆
The instruction of of replacing fan motor
1.Remove the
refrigerator
compartment
Accessories
2.
Remove the air
duct cover screws
3.Remove the air duct
Board
4.Open air duct Board
11
Compulsory defrost:
Connecting power within 1 minute, refrigerater or freezer door open situation, press Fridge and super
cool 3 seconds, enter the compulsory defrosting process:
——
--After entering the compulsory defrosting, we can run the defrosting same as the normal automatic
defrosting process.
——
Under compulsory defrosting process, displaying b area displays from 99 to 00.
After exiting the entire compulsory defrosting process, it reverts to normal operation and display.
The guide for Disassembly Common parts of Refrigerator
◆
The instruction of replacing the main board.
1. The location of the
electrical main board.
2. Unscrew electrical
box ( 2 screws ).
3. Remove the
electrical box.
4. Open the electrical
appliances lifted the
lid.
5. Unplug the
electrical wires.
6. Remove the main
board screw