BravoFIL S - ENGLISH
MAN166
PAG.EN-12
B1.5 Allowed installation schemes
The assembly should be performed respecting one of the schemes indicated here below:
Installation 1.
Left entrance
Right exit
Installation 2.
Bottom entrance
Top exit
Installation 3.
Right entrance
Left exit
Installation 4.
Top entrance
Bottom exit
Any other arrangement may cause the no proper operation of the device.
BravoFIL S can be installed horizontally and vertically but with the filter drain always facing
downwards.
Warning!
It is necessary to install the filter following the water flow direction indicated by
the row stamped on the brass head of the filter.
BravoFIL S owns a 360° brass connection plate that can turn at intervals of 90°. In order to change
the orientation of the brass connection plate it is enough to untight the allen nuts (using a 6 mm
allen wrench). Orientate the plate connection in the desired direction, taking care to position the
white shaped gasket sited between the brass plate and the acetal resin white head in a correct
manner.
The filter drain connection must be conveyed into a visible drain in a stable manner.
In case of doubt contact with Acqua Brevetti SRL (Tel.: +39.049.8973432 or send an e-mail to
Follow the water flow
direction indicated by the
row stamped on the brass
head of the filter.
6 mm allen nuts to tight the
brass connection plate.