Component Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor  
before servicing, unless testing requires power. 

 

October 2013 

 

 

©2013 ACP, Inc. 

16500048

 

 

3

 

Illustration 

Component 

Test 

Results 

 

 

 

Terminal 1 

 

  220 V 

Terminal 2 

 

 Common 

 

Transformer 
 

 

Discharge Capacitors 

Remove all wires from terminals. 
Measure resistance from: 
 
Terminal 1 to Terminal 2 ..................................  
Terminal 1 to Wire 3 ........................................  
Wire 3 to Wire 5 ..............................................    
Terminal 4  to Ground screw on transformer ...  
Terminal 4 to any other terminal ......................  

 

 
 
 
 
2.0 

Infinite. 
Less than 1 

160-170 

Infinite resistance. If not, 
replace transformer. 

Secondary
Interlock
Switch

Primary
Interlock
Switch

Monitor
Interlock
Switch

 

Interlock switch 
assembly 

Disconnect wires to switch. 
 
With door open measure resistance from: 
Terminal C to NC      Monitor ...........................  
Terminal C to NO      Primary / Logic ...............  
Terminal C to NO      Secondary ......................  
 
With door closed measure resistance from: 
Terminal C to NC      Monitor ...........................  
Terminal C to NO      Primary / Logic ...............  
Terminal C to NO      Secondary ......................  
 

Door Closed

 

Primary / Logic C

NC

NO

C

C

NO

Secondary

Monitor

 

 

 
 
 
Continuity. 
Infinite. 
Infinite. 
 
 
Infinite. 
Continuity. 
Continuity. 

Wire Harness 

 

Test continuity of wires ....................................  

Continuity. 

 

Содержание RMS510TS

Страница 1: ... of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models RMS510TS Power Source Voltage AC 220 VAC Amperage Single Unit 15 A Frequency 50 Hz Single Phase 3 wire grounded X Receptacle AW208 AWIN Plug AW208 AWIN Power Output Nominal microwave energy IEC705 1000 Watts Minimum temperature rise T 10º F 5º C Opera...

Страница 2: ...ghest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace capacitor Terminal to Case Infinite resistance Magnetron Discharge Capacitors Remove wires from magnetron and connect ohmmeter to terminals Also check betwe...

Страница 3: ...w on transformer Terminal 4 to any other terminal 2 0 Ω Infinite Less than 1 Ω 160 170 Ω Infinite resistance If not replace transformer Secondary Interlock Switch Primary Interlock Switch Monitor Interlock Switch Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NC Monitor Terminal C to NO Primary Logic Terminal C to NO Secondary With door cl...

Страница 4: ... NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 5 At end of the cycle re...

Страница 5: ...tic Diagrams WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power October 2013 2013 ACP Inc 16500048 5 DANGER ...

Отзывы: