Component Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor  
before servicing, unless testing requires power. 

 

 

 

October 2013 

16500048 

©2013 ACP, Inc.

 

2

 

Illustration 

Component 

Test 

Results 

 

Thermal Cutout 

Disconnect all wires from TCO. 
Measure resistance across terminals. 
Cavity Thermal Fuse ......................................
Magnetron TCO .............................................

 
 
Open at 230° F (110° C). 
Open at 320° F (160° C). 

 

Diode Assembly 

Discharge Capacitor

 

 
Remove diode lead from capacitor and 
connect ohmmeter. 
 
Reverse leads for second test. 

Infinite resistance should be measured 
in one direction and 50K

 or more in 

the opposite direction. 
 

NOTE:

 Test meter must contain a 

battery of 6 volts minimum. 

 

Capacitor 

Discharge Capacitor

 

 
Remove wires from capacitor terminals and 
connect ohmmeter, set on highest 
resistance scale to terminals. 
 
 
 
Also check between each terminal and 
capacitor case. 

 
 

Between Terminals:

 Meter should 

momentarily deflect towards zero then 
return to over 5 M

. If no deflection 

occurs, or if continuous deflection 
occurs, replace capacitor. 
 

Terminal to Case:

 Infinite resistance. 

 

Magnetron 

Discharge Capacitors

 

 
Remove wires from magnetron and connect 
ohmmeter to terminals. Also check 
between each terminal and ground. 

Between Terminals:

 Less than 1 

 
Each terminal to ground measures 
Infinite resistance. 

NOTE:

 This test is not conclusive. If 

oven does not heat and all other 
components test good replace the 
magnetron and retest. 

 

Stirrer Motor 

Remove all wires from terminals. 
 
Measure resistance from: 

terminal to terminal ......................................

 
 
 
Approximately 10 K

 

Blower Motor 

Remove all wires from motor. 
 
Measure resistance from terminal to 
terminal… .......................................................

 
 
 
Approximately 435 

 

Fuse block / Filter 
assembly 

Power In terminals ......................................  
Power Out terminals ...................................  

230 VAC 
230 VAC 
If no power in, check power outlet 
If no power out, check fuses 

Содержание RMS510TS

Страница 1: ... of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models RMS510TS Power Source Voltage AC 220 VAC Amperage Single Unit 15 A Frequency 50 Hz Single Phase 3 wire grounded X Receptacle AW208 AWIN Plug AW208 AWIN Power Output Nominal microwave energy IEC705 1000 Watts Minimum temperature rise T 10º F 5º C Opera...

Страница 2: ...ghest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace capacitor Terminal to Case Infinite resistance Magnetron Discharge Capacitors Remove wires from magnetron and connect ohmmeter to terminals Also check betwe...

Страница 3: ...w on transformer Terminal 4 to any other terminal 2 0 Ω Infinite Less than 1 Ω 160 170 Ω Infinite resistance If not replace transformer Secondary Interlock Switch Primary Interlock Switch Monitor Interlock Switch Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NC Monitor Terminal C to NO Primary Logic Terminal C to NO Secondary With door cl...

Страница 4: ... NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 5 At end of the cycle re...

Страница 5: ...tic Diagrams WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power October 2013 2013 ACP Inc 16500048 5 DANGER ...

Отзывы: