background image

Commercial Microwave

Technical Information

 

October 2013 

 

©2013 ACP, Inc. 

16500048

 

230V, 50 Hz Models 

RMS510TS   P2001218M  

 

 

Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or 
repair of this unit. 

  Refer to Service Manual for installation, operating, testing, troubleshooting, and disassembly instruction. 

CAUTION

!

 

All safety information must be followed as provided in Service Manual. 

!

WARNING

 

To avoid the risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor 
before servicing, unless testing requires power. 

Models 

RMS510TS  

Power Source

 

 

Voltage AC 

220 VAC 

Amperage (Single Unit) 

15 A 

Frequency 

50 Hz 

Single Phase, 3 wire grounded 

Receptacle 

AW208 AWIN 

Plug 

AW208 AWIN 

Power Output

 

 

Nominal microwave energy (IEC705) 

1000 Watts 

Minimum temperature rise (

T) 

10º F / 5º C 

Operating Frequency 

2450 MHz 

Power Consumption

 

 

Cook Condition Microwave 

1150 Watts 

Dimensions 

 

Cabinet 

 

Width 

508 (20") 

Height 

311 (

12 1/4") 

Depth 

419 

(16 1/2") 

Oven Interior

 

 

Width 

330.2 (13") 

Height 

197 (7 3/4") 

Depth 

330.2 (13") 

Weight

 

 

Crated 

14.5 kg. (39 lbs.) 

Uncrated 

17.7 kg. (32 lbs.) 

 

Содержание RMS510TS

Страница 1: ... of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models RMS510TS Power Source Voltage AC 220 VAC Amperage Single Unit 15 A Frequency 50 Hz Single Phase 3 wire grounded X Receptacle AW208 AWIN Plug AW208 AWIN Power Output Nominal microwave energy IEC705 1000 Watts Minimum temperature rise T 10º F 5º C Opera...

Страница 2: ...ghest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace capacitor Terminal to Case Infinite resistance Magnetron Discharge Capacitors Remove wires from magnetron and connect ohmmeter to terminals Also check betwe...

Страница 3: ...w on transformer Terminal 4 to any other terminal 2 0 Ω Infinite Less than 1 Ω 160 170 Ω Infinite resistance If not replace transformer Secondary Interlock Switch Primary Interlock Switch Monitor Interlock Switch Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NC Monitor Terminal C to NO Primary Logic Terminal C to NO Secondary With door cl...

Страница 4: ... NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 5 At end of the cycle re...

Страница 5: ...tic Diagrams WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power October 2013 2013 ACP Inc 16500048 5 DANGER ...

Отзывы: