
OMNISTIM
®
500 PRO USER MANUAL
7
COPYRIGHT © 2004 - 2018, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED
K.
Output for CHANNEL A and HVPC protocols.
L.
Output for CHANNEL B.
M.
Increase / decrease OUTPUT A. Press UP arrow button to increase intensity in channel A. Press the DOWN
arrow button to decrease intensity in channel A.
N.
Increase / decrease OUTPUT B. Press UP arrow button to increase intensity in channel B. Press the DOWN
arrow button to decrease intensity in channel B.
O.
LED which lights-up red when output is being applied thru channel B.
P.
LED which lights-up red when output is being applied thru channel A.
Q.
START/STOP button. Having selected the type of treatment and protocol, press to start or stop the treatment.
R.
LCD graphics screen for all functions and parameters. The graphics screen displays:
•
Protocol selected
•
Program selected
•
Time remaining
•
Carrier Frequency
•
Bar graph for Vector and detection modes
•
Button speeds
•
Vector selection
•
Output current
•
Sweep rate and modulation selection
S.
PROTOCOL LABEL to assist therapist in quick operation and treatment selection.
T.
Power Supply input jack.
U.
Power Supply operation indicator LED. This light is on when the power supply is plugged in and power is
supplied to the unit.
V.
Solid carrying handle for easy transport of the unit.
Factory Settings
The Omnistim
®
500 Pro comes with the following factory settings:
Button Speed, A & B Output
91
Audio
ON
These are generally suitable for most clinicians. To adjust these default settings proceed as follows:
1.
When the main screen comes up and states “SELECT PROTOCOL / TREATMENT OFF” push the
SELECT PARAMETERS button repeatedly to display the factory settings. You will then be able to adjust
the selected factory settings by pressing the MODIFY TIME/PARAMETER UP / DOWN arrow button.
The new settings will be saved from use to use as long as you do not remove the batteries or allow a full
discharge of the unit.
2.
The BUTTON SPEED for output A & B sets the speed at which output will increase and decrease when
you push the buttons. This should generally be set at a slower speed (80 - 90) so as not to startle the patient.
3.
AUDIO on or off disables or enables the audio system that beeps at the end of the treatment and during the
NMES programs.
NOTE:
The factory settings cannot be accessed during operation and are only available following the
start up screen. The settings will reset to their initial default parameters if the batteries are removed or the
unit is fully discharged. To restore the new settings follow the procedure in Appendix I.