![ACP MXP5201 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/acp/mxp5201/mxp5201_service-manual_2840412021.webp)
19
Display Diagnostics
Display Description
Corrective Action
B0
Touch Panel
Replace Touch Panel
B1
Touch Panel
Replace Touch Panel
C-0
Temp Sensor (RTD) (open)
Replace Temp Sensor
C-1
Temp Sensor (RTD) (shorted)
Replace Temp Sensor
C-2
Temp Sensor (RTD) (out of range)
Replace Temp Sensor
D-0
Thermocouple (RTD) (open)
Replace Thermocouple
D-1
Thermocouple (RTD) (shorted)
Replace Thermocouple
D-2
Thermocouple (RTD) (out of range) Replace Thermocouple
G-0
Oven Exceeded max. Temp.
Unplug / Plug oven in*
G-2
magnetron TCO
Perform service test (Magnetron #1 & #2)
G-2
Cooling Motor
Perform service test (Cooling Fan)
H-0
Signal Missing
Plug disconnected from J1 on main board
H-1
Main Board Set Point Incorrect.
Unplug / Plug oven in
H-2
Main Board
Replace main board
H-3
Main Board
Replace main board
M-0
Current Sense Low Amps
Perform service test (Magnetron #1 & #2)
M-1
Magnetron 1 Low Amps
Perform service test (Magnetron #1)
M-2
Magnetron 2 Low Amps
Perform service test (Magnetron #2)
Note:
While in the service test the error history can be cleared by pressing and holding Pad 1
see page 27.
*If G-0 continues to appear. Replace Electronic Limiter.
Error Codes