34
Troubleshooting
Standby Condition
Blower motor operates?
Inoperative blower motor.
Inoperative auto-transformer.
Broken or improper wire connections.
1.
2.
3.
"Standby Condition" normal - proceed to
"Cook Condition".
Yes
Yes
Open oven door.
Oven light is on?
Antenna motor(s) operate?
Inoperative light bulb.
Inoperative light socket.
Inoperative auto-transformer.
Broken or improper wire connections.
1.
2.
3.
4.
Inoperative antenna motor.
Binding gears (bottom antenna only).
Inoperative auto-transformer.
Broken or improper wire connections.
1.
2.
4.
5.
Inoperative interlock switch assembly (logic or primary).
Inoperative control board.
Broken or improper wire connections.
1.
2.
3.
NO
Inoperative control board.
5.
NO
NO
NO
Yes
Yes
Display
Grease shield installed upside down
(top antenna only).
3.
Содержание Menumaster DEC21E2
Страница 1: ...Service Training Manual Compact Models DEC 50 Hz CHDC 50Hz Chinese Oven September 2011 16400016 ...
Страница 3: ...1 Important Safety Information 1 ...
Страница 13: ...11 DEC 50 Hz Components 4 ...
Страница 18: ...16 Components Sample Door Assembly 5 6 7 8 7 9 7 7 6 6 7 6 ...
Страница 19: ...17 Disassembly Inner door window removal Switch replacement door adjustment 5 ...
Страница 26: ...24 Airflow 7 ...
Страница 27: ...25 Air filter must be in place and cleaned regularly Some Models ...
Страница 28: ...26 Component Testing Procedures 8 ...
Страница 34: ...32 Troubleshooting Intial Power Up Standby Condition Cook Condition 9 ...
Страница 38: ...36 Wiring Diagrams Schematics 10 ...
Страница 47: ...45 Notes ...
Страница 48: ...www acpsolutions com 01 23 45 6 7 7 8 94 7 1 8 1 ...