ARX1 / MRX1 Estimated Heat Load Calculations
ARX1/MRX1 (single phase)
Parameters
Operating Time
12 Hours
Energy Costs
$0.11 KWHr
Idle Time
2 Hours
Cook Cycles/Daily
100
Typical Cook Time
60 Seconds
Data
Time
(Minutes)
Power
(Watts)
kWh
Cost/Day
Balance of
Time
(Hours)
Warm Up
9
2,990
0.4
$0.05
11.85
Cooking
100
3,223
5.4
$0.59
10.15
Idle Time
611
927
9.4
$1.04
0.00
TOTAL COST PER DAY $1.68
TOTAL COST PER MONTH $50.36
TOTAL COST PER YEAR $604.30
HVAC Requirements per Operating Time (Estimated)
Average
Energy
Cooking
and Idle
Warm-Up
Energy
Total
Energy
Total
Average
Power
Total
Environmental
Load
Average
Cooling
Requirement
53,322 kJ
1,615 kJ
54,936 kJ
1,272 W
4,339 Btu/hr
0.36 Tons of
AC
Page 12 of 26