Step 5

 

Adjust the clearance underneath the acrylic arm, 

so that the acrylic arm is horizontal.

Step 6

 

Slide the UNI-P2S into place in the direction of 

the tonearm’s bearing house/pivot.

Step 7

 

Do mount the long stainless steel positioning pin 

with the reticule either on top or pointing down

-

ward into the nylon tunnel. It will fit quite tight 

- handle with care, as the tip is sharp and may 

cause injuries. Do untight the black screw on the 

POM-block carrying the metric scale. Slide the 

metric arm with the pin toward the center of the 

arm bearing house.

If you can spot the center, use the pin-point.

Try to locate pin exact over the pivot center.

If unsure of pivot center, do use the reticule and 

determine pivot center by finding symmetrical 

outer lines on the bearing house.

Step 8

 

When pivot center is directly underneath the pin, 

do fasten the screw holding the metric scale in 

place.

Now look on the scale on the POM block.

Содержание UNI P2S

Страница 1: ...owner s manual UNI P2S Universal high precision phono pivot to spindle P2S direct measuring instrument ...

Страница 2: ...prior notice version 16 02 DISCLAIMER Please use all parts with care The use of the UNI P2S is on your own risk The manufacturer and the designer do not take any responsibility for possible damage or injury due to operate or handle the UNI P2S or any of it s parts Keep out of reach of children ...

Страница 3: ...P Wally Dennesen Soundtraktor Schön template 1 and 2 A brief introduction This means you can use the UNI P2S mounted WHILE any of the above mentioned protractors are in use and thus checking mounting distance on the fly while aligning the tonearm cartridge It further offers precise help with some protractors so you can determine the proper orientation of help lines towards the pivot To ensure the ...

Страница 4: ...r for the measuring Setup Step 2 Place the selected tt spindle adapter over the turn table s spindle It should fit without any play Step 3 Place the clamp opening on the UNI P2S acrylic arm over the tt spindle adapter Step 4 It will give a frim tight grip yet it will allow free circular movement around the spindle ...

Страница 5: ... as the tip is sharp and may cause injuries Do untight the black screw on the POM block carrying the metric scale Slide the metric arm with the pin toward the center of the arm bearing house If you can spot the center use the pin point Try to locate pin exact over the pivot center If unsure of pivot center do use the reticule and determine pivot center by finding symmetrical outer lines on the bea...

Страница 6: ...r 5 100 mm each Whenever any of the white lines is absolutely in line with a black line on the aluminum scale then it denominates the 5 100 value which has to be added to the full mm value given between the 2 white leaves centered by the full vertical white line on the left of the scale just before the half circle end To illustrate the read out procedure here are a few examples of mounting distanc...

Страница 7: ...n end of the pen first Draw an arc You now may adjust height and draw and arc on your armboard plinth That arc gives all prospective positions for mounting the respective tonearm with the desired mounting distance Drilling hole You may use a small hammer and a low force hit on the gun metal cap holding the reticule to mark a drilling hole in the armboard ...

Страница 8: ...m Pioneer Exclusive 269 5 mm SAEC 407 221 0 mm 308 235 0 mm 308L 265 0 mm Reed 3Q 9 5 223 0 mm 10 5 251 6 mm 12 295 6 mm SAEC 506 286 0 mm WE 8000 293 0 mm SME Series V 215 35 mm 3012 294 0 mm Talea 247 37 mm Technics all EPA series 235 0 mm Tri Planar 233 5 mm Please note these are all values given by the manufacturer The alternative 231 5 mm for the FR 64s however is a personal recommendation We...

Отзывы: