background image

4

Step 1 

 

 

The SMARTractor is already pre-assembled  

with the 20 mm POM spindle ring (part of the uni-

versal 3-part spindle-adapter) sitting in the center 

of the SMARTractor. 

First place the SMARTractor - with the 20 mm 

POM spindle ring -  on the spindle.

Setting up the  

SMARTractor

Step 2 

 

 

Now take the 

12 

mm (tall) or 6 mm (short 

and wide collar) spindle ring insert**

 . Now 

SLOWLY

 and 

CAREFULLY

 place it on the top 

of the spindle and ever so slightly press down.

 

Step 3

IMPORTANT - be carefull!  

** 12 mm or 6 mm spindle insert ??

  

The 12 mm (tall) insert will work with small diameter spindles (smaller 

then 7.15 mm diameter). The 6 mm (wide) insert will work with 7.2 and 

wider diameter.

Do not press down the spindle adapter too hard or too deep. On some 

spindle it will only be 2-3 mm or less. If you press too hard, you will 

have a very hard time getting the white 20 mm POM ring off your 

spindle again.

The 12 mm and / or 6 mm spindle adapter insert allows the precise  

centering of the SMARTractor on a wide range of spindle diameters.

Remember - Please be careful and do not use any excessive force.  

Pushing down realy hard creates a  VERY tight lock which you will 

have big problems loosening up again.

Measuring P2S

20 mm spindle ring

and 12 mm insert

UNI P2S

If you want to measure the arm mounting  

distance or P2S, rotate the central block to the 

UNI P2S 

position, loosen the locking screw  

fixing the positioning arm in the black POM 

block.  

 

The engraved line on the center piece will meet 

the line at “

UNI P2S

”.

 

Slide the central assembly back or forth so that 

the hole for the thumbscrew is aligned with the 

locking thread for the selected curve - there is 

only 1 possible thread hole to move to in each 

position.

Fix the assembly in place by re-installing and 

tightening the thumbscrew.  The thumbscrew need 

only be very snug by hand tension.

Содержание SMARTractor

Страница 1: ...Universal high precision triangular positioning alignment instrument for optimized analog phono tonearm alignment true one point cartridge set up owner s manual SMARTractor acoustical systems ...

Страница 2: ...rior to shipment Please do get yourself familiar to the handling and use of the SMARTractor While it is a mechanical positioning instrument it needs a minimum of attention to detail by the user to obtain the maximum precise results it ensures if handled correctly A brief introduction Most important Please study the step by step illustrated instruction to learn how to use and set up the SMARTractor...

Страница 3: ...SMARTractor an additional 20 mm of height for the positioning arm in those instance where required for illustration see page 8 The SMARTractor offers a total of 5 different tangential curves with which to align a given cartridge and tonearm combination Selecting the tangential curve You have the option to align the cartridge using any of these five tangential curves UNI DIN 1 Loefgren B DIN 2 Loef...

Страница 4: ...very hard time getting the white 20 mm POM ring off your spindle again The 12 mm and or 6 mm spindle adapter insert allows the precise centering of the SMARTractor on a wide range of spindle diameters Remember Please be careful and do not use any excessive force Pushing down realy hard creates a VERY tight lock which you will have big problems loosening up again Measuring P2S 20 mm spindle ring an...

Страница 5: ...ing where the exact pivot point is located This is ideal for precise positioning of the locator pin on the pivot point If there is no indication of the tonearm pivot point attempt to locate pin exactly over the tonearm pivot center If unsure of pivot center use the reticule to visually determine tonearm pivot point by finding symmetrical outer lines on the tonearm body Step 6 When the pivot point ...

Страница 6: ...e left of the scale just before the half circle end To illustrate the read out procedure here are a few examples of mounting distances for common tonearms One will become accustom quite quickly to this way of reading the scale The Vernier scale is an international standard in industrial precision analog measuring The magnifier Using the glass magnifier greatly increases the visibility of the stylu...

Страница 7: ...mounting screws after final position is obtained Step 9 When the stylus is precisely sitting on the single spot use the helping lines to ensure that the cantilever is perpendicular to the SMARTractor surface when viewed from the front Adjust the cartridge accordingly until the cantilever is visually in this position If you have a Uni Pivot design tonearm it is critical that the table is level befo...

Страница 8: ... Hofstetten Germany www acoustical systems com info acoustical systems com Step 10 Make sure that the stylus is precisely located on the spot with the helping lines straight with the cantilever making sure that the locator pin is still exactly positioned over the pivot When you are sure that the stylus is precisely located on the spot with the helping lines in line with the cantilever the tangenti...