ORION MINI-REP V2 - RS-232 interface

 

One single repeater connection 

 

 

NOTE:

 Maximum of 1 ORION MINI-REP V2 with INT-RS232-WIRE (for multi-rep use INT-RS485-DTL). 

Maximum distance between Panel ORION MINI-REP should be 100 meters.

 

 

ORION MINI-REP V2 - RS-485 interface 

Multi repeater connection until a maximum of 4 

 

 

 

NOTE:

 If more than one Repeater is connected, in order for them to work properly some configurations 

are needed. Please refer to  the “ADDRESSING THE PANEL” section in this manual.

 

 

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание ORION MINI-REP

Страница 1: ...S232 interface Power for the ORION MINI REP V2 can be supplied from the control panel s auxiliary power output or from an external 24 Volt DC power supply if required IMPORTANT SAFETY NOTES This equipment must only be installed and maintained by a suitably qualified and technically competent person A basic knowledge and training in the installation of Fire Detection Systems is assumed The Fire Det...

Страница 2: ...ion All connections should be performed with all elements of the Fire Detection System unpowered The Repeater should be located where access to the internal components is not restricted and where the unit is not exposed to high levels of moisture vibration and shock WARNING Observe ESD precautions when handling the PCBs All cables should be screened WARNING Cable screen s should only be connected ...

Страница 3: ...CONNECTION DIAGRAMS ORION MINI REP V2 General hardware and connections layout 3 www acornfiresecurity com www acornfiresecurity com ...

Страница 4: ...stance between Panel ORION MINI REP should be 100 meters ORION MINI REP V2 RS 485 interface Multi repeater connection until a maximum of 4 NOTE If more than one Repeater is connected in order for them to work properly some configurations are needed Please refer to the ADDRESSING THE PANEL section in this manual 4 www acornfiresecurity com www acornfiresecurity com ...

Страница 5: ...ve been disabled in either Access Level 2 or 3 modes Check ORION for detailed information TEST This LED is active whenever panel is in TEST MODE Only activated when in Engineering Mode and TEST mode has been selected at the ORION panel SUPPLY This LED signals the presence of Supply Additionally when in Access Level 1 this LED is permanently on If in Access Level 2 USER CODE 2244 this LED will flas...

Страница 6: ...ONTROLS AUTHORISED USER CODE 2244 Some keys will only be operational at the repeater after entering the authorised user code If the operation of a switch is only available after successfully entering the authorised user code it will be clearly stated in this manual that these functions are only active at Access Level 2 NOTE If active please SILENCE INTERNAL BUZZER before entering code The four num...

Страница 7: ...esponds to the desired Address is ON please refer to the table below for additional details 6 Confirm the selection by pressing GREEN 1 key Upon confirmation the Red FIRE LED will be activated Remove selection by pressing the GREEN key again The corresponding LED will be switched OFF 7 Exit function pressing OUTPUTS AUXILIARY button 8 RESET the repeater by pressing the RESET key 9 Repeat steps 3 t...

Отзывы: