FIXTURE ANCHORING
Part #: 6215-370-000
Page 11 of 30
mounting brackets pre-installed
onto the fixture.
FYI: Fixtures are shipped with wall
3
1
4
4
2
1
4
2
Secure compliant station portions of fixture 2 , (ADA, OBC etc...) to mounted angle brackets 1 with
¼-20 hex head cap screws, lock washers and fender washers 4 provided.
Secure remaining mounted angle brackets 3 to wall & starting with the flat or requirement portion
Place fixture on mounted angle brackets 1 and align the remaining mounted angle brackets 3 with
installed wall anchors. Fasten to wall loosely and proceed to step D.
of fixture 2 adjust and level as required. Do not over tighten.
C.
D.
E.
NOTE: It may be advantageous to install to the deck, faucets, soap
dispensers or other accessories prior to wall mounting.
Angle brackets 1 from compliant station of
fixture 2 . Loosen remaining angle brackets
3 but keep finger tight.
Disassemble fixture from crate and remove
A.
Anchor the free angle brackets 1 to
finished wall using installer provided ½”
anchoring hardware (4 places). Level and
plumb as required. All wall anchors and wall
anchoring hardware are by others.
B.
!
IMPORTANT
Compliant station portion of fixture refers to
station(s) that are intended to meet ADA,
OBC or other accessibility standards required.