ROUGH-IN DIMENSIONS -OBC
ONTARIO BUILDING CODE
MOUNTING
PLUMBING
A - Wall Anchoring for .563" Diameter x 1" Long, Angle Bracket Mounting Slots, 8 Places.
B - Supply Stub-Outs with Stops for Valve 1/2" NPT Hot & Cold Supply Inlets.
E - Wall Anchoring for .219" Diameter x 3/8" Long, Enclosure Mounting Slots,10 Places.
D - 120VAC, 60 Hz, 3A (Max.) GFCI Protected, Electrical Receptacle.
F - Valve Mounting Area.
C - Waste Outlet for 1-1/2" O.D. P-Trap Provided.
Part #: 6215-370-000
3752-HLL SHOWN
3752-HLR OPPOSITE
4" TYP
16
1
2
"
22"
33" Rim
Max.
6"
22"
30"
22"
60"
4"
4"
4"
33"
2"
5"
9"
15"
7
1
2
"
18"
A
A
A
A
D
C
B
B
15"
13
1
4
"
26
1
2
"
1
3
4
"
C
15
1
8
"
26
3
8
"
F
D
E
E
E
E
E
E
E
E
E
E
13
1
4
"
1
3
4
"
6"
20
3
8
"