Condition 1:
Actual charging power of PV array ≤ Rated charging power of controller
Condition 2:
Actual charging current of PV array ≤ Rated charging current of controller
When the controller operates under “
Condition 1
”or“
Condition 2
”, it will carry out
the charging as per the actual current or power; at this time, the controller can work
at the maximum power point of PV array.
WARNING:
When the power of PV is not greater than the rated
charging power, but the maximum open-circuit voltage of PV array is
more than 100V (at the lowest environmental temperature), the
controller may be damaged.
Condition 3:
Actual charging power of PV array
>
Rated charging power of controller
Condition 4:
Actual charging current of PV array
>
Rated charging current of controller
When the controller operates under “
Condition 3
”or“
Condition 4
”
,
it will carry out
the charging as per the rated current or power.
WARNING:
When the power of PV module is greater than the rated
charging power, and the maximum open-circuit voltage of PV array is
more than 100V (at the lowest environmental temperature), the
controller may be damaged.
According to “Peak Sun Hours diagram”, if the power of PV array exceeds the rated
charging power of controller, then the charging time as per the rated power will be
prolonged, so that more energy can be obtained for charging the battery. However,
in the practical application, the maximum power of PV array shall be not greater
than 1.5 x the rated charging power of controller. If the maximum power of PV
array exceeds the rated charging power of controller too much, it will not only
cause the waste of PV modules, but also increase the open-circuit voltage of PV
array due to the influence of environmental temperature, which may make the
probability of damage to the controller rise. Therefore, it is very important to
configure the system reasonably. For the recommended maximum power of PV
array for this controller, please refer to the table below:
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
Содержание Midas Y Series
Страница 11: ...Installation Procedure Mounting Instruction Figure 2 1 Mounting 150mm 150mm 150mm 150mm 08...
Страница 37: ...Annex II Mechanical Dimension Diagra MY20 Unit mm 149 217 28 5 160 56 5 7 5 R2 5 158 34...
Страница 38: ...MY30 Unit mm 156 230 28 5 173 63 7 5 R2 5 165 35...
Страница 39: ...MY40 Unit mm 176 255 27 5 200 67 8 7 5 R2 5 185 36...
Страница 40: ...Add 4120 Valley Blvd Walnut CA 91789 USA Tel 1 626 575 7722 Email sales acopower com Web www acopower com...