Replacing the Disk Drive
ARX®1000 Hardware Installation Guide
A - 5
For example, the following command shows that the rebuild is 21%
complete. The rebuild progress is shown in bold:
prtlndA1k#
show chassis diskuse
Logical Disk Details:
Disk Status Verification Mode Verification Rate
------ --------------------- ----------------- -----------------
1 Optimal Manual 10 %
Disk Details:
Disk Size State Transfer Rate Model
-------- ----------- ----------------- ------------- -----------------
Bay 1 68.50G Online 320MB/sec ATLAS10K4_73SCA
Bay 2 68.50G
Rebuild 21%
320MB/sec ATLAS10K4_73SCA
RAID Controller Details:
Rebuild Rate Max Transfer Rate Firmware RAID Alarm
------------ ----------------- ------------- ------------
90 % 320MB/sec TL37:G117 Enabled
Disk Usage:
Name Total MB Used MB Free MB Used%
-------------------------------- ---------- ---------- ---------- -----
System 2121 998 1014 50%
Releases 4234 1701 2317 43%
Logs 2121 99 1914 5%
Cores; DiagInfo; Lists 8460 37 7993 1%
Reports; Scripts 46940 66 44489 1%
prtlndA1k#
...