Description and connection
Power terminals
Specifications of the input terminal block XA1
AC line
o
Input voltage
min. 200 V single phase
–15%
max. 3 phases 480 V
50 / 60 Hz
o
Single phase input connect to any 2 of L1, L2 or L3
o
External overload protection required.
Circuit breaker or line fuses
max. 32 AT
o
Use copper conductors
75°C
24 VDC external power supply
o
Voltage tolerances
10%
o
Required power min. 1 A per module up to ACO5020 and 3A min. for ACO5030R1
o
External overload protection required if not short-circuit proof
Specification of the output terminal block XD1
Motor power
o
Max. output voltage 3 phases 480 V, 5000 Hz
o
Use power cable according to the recommendation of the motor manufacturer
o
Cable gauge according the motor current requirements
PTC input
o
This input is over voltage proof up to 500 VAC
o
In case of use of temperature sensor, program the appropriate input calibration.
ACO5000A ACO50xxD
TERMINAL BLOCK XA1
24 VDC INPUT
0 V
PE Principal Earth
Mains input L3
L2
L1
All terminals 10 mm
2
One block,
removable
External overload
protection required
TERMINAL BLOCK XD1
PTC INPUT
PTC INPUT
Earth
W motor output
V
U
All terminals 10 mm
2
One block, removable