Acom SI-1 Скачать руководство пользователя страница 2

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

TABLE OF CONTENTS

 SPECIFICATIONS 

 

.......................................................... 

 NOMENCLATURE 

 

 

......................................................... 

 

FUNCTION KEYS   ..........................................................  2 

 DISPLAY 

 

 

........................................................................ 

 

UNPACKING & ASSEMBLY  ...........................................  3 

 

SAFETY PRECAUTIONS  ...............................................  4 

 

OPERATING THE SCALE  ..............................................   4 

 

TROUBLESHOOTING & ERROR MESSAGES  .............  7 

 
 
 
 
 
 

PREFACE 

A

COM

 Corporation would like to thank you for purchasing our model SI-1 

Advanced Bench scale.  We are committed to creating high quality low 
maintenance products and supplying our customers with diligent customer 
service. This manual contains information on the proper assembly and use 
of the scale. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Brand and product names are trademarks and/or registered 
trademarks of their respective companies. 

This company makes no representations or warranties, either 
expressed or implied, with respect to the contents hereof and 
specifically disclaims any warranties of merchantability or fitness 
for any particular purpose.  Any software described in this manual 
is sold or licensed “as is”.  Should the programs prove defective 
following their purchase, the buyer (and not this company, its 
distributors, or its dealers) assumes the entire cost of all necessary 
servicing, repair, and any incidental or consequential damages 
resulting from any defect in the software.  Further, this company 
reserves the right to revise this publication and to make changes 
from time to time in the contents hereof without obligation to notify 
any person of such revision or changes. 

Disclaimer: 

Содержание SI-1

Страница 1: ...A A A ACOM COM COM COM OW N E R S M AN U AL MODEL SI 1 BENCH SCALE VER 1 00 ...

Страница 2: ... companies This company makes no representations or warranties either expressed or implied with respect to the contents hereof and specifically disclaims any warranties of merchantability or fitness for any particular purpose Any software described in this manual is sold or licensed as is Should the programs prove defective following their purchase the buyer and not this company its distributors o...

Страница 3: ... adjustable Units Modes pounds kilograms counting mode limit mode VFD Display 6 Digits 999999 max Platter Size Width 400 mm 15 7 Depth 525 mm 20 5 Width 400 mm 15 7 Depth 675 mm 26 6 Product Dimensions Height 850 mm 33 5 Input 120 Volts AC 60 Hz Power Requirements Output 9 Volts DC 300 mA Operating Temp 10 C 40 C 14 F 104 F Humidity RH 35 85 no condensation Power consumption Approximately 1 4 Watt...

Страница 4: ...ey no function Reserved for future use Display Zero lamp indicates that the scale is at net or gross zero Stable lamp indicates that the weight on the scale is stable Net lamp indicates that there is a tare set and that the displayed weight is the net weight When it is off it means that the displayed weight is the gross weight lb lamp indicates that the scale is displaying pounds kg lamp indicates...

Страница 5: ...Name Units QTY 3 1 IN CARTON BOX EA 1 3 2 STYROFOAM EA 2 3 3 BODY POLY BAG EA 1 3 4 MANUAL POLY BAG EA 1 3 5 AC ADAPTER EA 1 3 6 ADAPTER BOX EA 1 3 7 MANUAL EA 1 3 8 DISPLAY COLUMN EA 1 3 9 PLATFORM EA 1 3 10 INDICATOR EA 1 3 11 INDICATOR POLY BAG EA 1 3 15 SILICA DESICANT EA 2 ...

Страница 6: ... properly on top of the platform and that there is nothing on top of the platter Also make sure that the scale is plugged into the proper outlet Place the power switch into the ON position The display will run through a self test and then go to zero The scale will always remain in the last mode that it was left in The display may appear as follows it will read 0 0 if it is a 300 lb scale Changing ...

Страница 7: ...ZERO and STABLE Simple Weighing Using Tares 1 Make sure that the scale is at ZERO and STABLE 2 Follow directions for entering a tare 3 Place a load on the platter 4 After the STABLE indicator turns on you may read the weight 5 Remove the load 6 You may continue to use the same tare by returning to step 3 in this procedure OR continue to step 7 7 Follow steps for Removing Tares Parts Counting This ...

Страница 8: ...b 2 kg 10 lb 5 kg Maximum Quantity 3 000 pcs Limit Mode lb only 1 Press the MODE key until you reach Limit mode Limit 2 Make sure that the scale is at ZERO and STABLE 3 If necessary follow directions for entering a tare 4 Press the SET key 5 The display will read Lo and then 0 00 or 0 0 6 Place the Low Limit load on the platter and press the SET key 7 The scale will display SEt momentarily and the...

Страница 9: ...ing on or obstructing the platter Turn scale on with the platter properly placed on the scale EEP E2 PROM failure Contact Service AdC A D Converter failure Contact Service PArA Lost memory Possibly reprogram and recalibrate Contact Service Brand and product names are trademarks and or registered trademarks of their respective companies ...

Страница 10: ...Acom America Inc 404 Paulding Avenue Northvale NJ 07647 www acomamerica com Copyright 2001 All rights reserved 800 10006 020000 ...