Page 33 of 33
i) Mains power consumption in Low Energy (waiting) mode: less than 1VA;
j) Complies with EU safety regulations and electromagnetic compatibility standards, as well as with the US
Federal Communications Commission (FCC) rules;
k) Environment working conditions:
-
temperature range: -10ºC to +40ºC (14ºF to 104ºF);
-
relative air humidity: up to 95% @ 35ºC (95ºF);
l) Dimensions (projections not included) and weight, operating: (W x H x D) 330 x 165 x 380 mm (13 x 6.5 x
15 In); 12 kg (26.5 Lbs).
8-2. Functions
a) Receive / transmit control:
- KEY-IN input – type Phono (RCA) jack socket; voltage fed to the open transceiver key: not exceeding
+12.6V; current through the closed transceiver key: not exceeding 6mA;
- not obligatory KEY-OUT output – type Phono (RCA) jack socket; output resistance: not more than 120
Ohm; maximum admissible input voltage from the transceiver (across an open KEY-OUT output): +50V;
maximum admissible current through a closed KEY-OUT output: 20mA;
- minimum dead time, necessary for safe amplifier switching from receive to transmit: 10ms between
transmit request at the KEY-IN input jack and the RF drive appearance at the RF INPUT connector.
b) Frequency control directly from CAT interface of the transceiver – connector CAT/AUX (connector type
DB-15).
c) Remote control through RS232 interface (connector type DB-9).
d) Remote turn on through simultaneous activation of the signals DSR/DTR and CTS/RTS on the RS232
(type DB-9) connector.
e) Remote turn on / turn off line – “ON_RMT” input on the CAT/AUX (DB-15) connector; DC voltage pulse:
+4.5 to +15V DC towards ground for 1-2s; input current: 3mA maximum.
8-3.
Storage and shipment
a) Environment conditions for storage and shipment:
-
temperature range: -40ºC to +70ºC (-40ºF to 158ºF);
-
relative air humidity: up to 75% @ 35ºC (95ºF);
-
above sea-level: up to 12000m, including the luggage compartment of aircraft.
b)
Dimensions and weight at transportation (max): (W x H x D) 480 x 280 x 440 mm (18.9 x 11 x 17.3 In);
14.5kg (32 Lbs).
9. DISCLAIMER of LIABILITY
All ACOM 600S specifications and descriptions are based on the latest information available at the time
of this document’s printing. As we always strive to constantly improve and update our products, ALL
PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE and ACOM
reserves the right to make changes and improvements at any time without further notice or obligation to
notify any person or organization of such revisions or changes, made in order to improve the reliability,
function, quality and design, and/or performance of the ACOM 600S. Further, this Operating Manual is
provided “as is” and ACOM shall not be liable for possible errors contained herein.