Acom 3x2000A Скачать руководство пользователя страница 5

 

2. INSTALLATION 

2-1. Unpacking and Initial Inspection 

N O T E 

Before you start any action on installing the splitter / combiner, thoroughly read through this 

manual. First, carefully inspect the cardboard carton and its content for physical damage. If 

damage is noticed, notify your dealer immediately. Delay may infringe carrier's warranty 

conditions. Keep all packing for possible future transportation!  

2-2. Preparation of the system units  

N O T E 

The three amplifiers used with the ACOM3x2000A splitter / combiner should all be of same type 

and with same settings, which can affect their gain or voltage selector for instance. 

   

The device is designed to be used with three ACOM2000A automatic amplifiers, but it could be used 

also with three ACOM1200

,

 ACOM1000, ACOM1010 or ACOM1011 manual tune amplifiers. 

   

 

N O T E 

The transceiver used should produce enough power to drive the three amplifiers, i.e. triple the 

drive power required by each amplifier for the needed output. Add some overhead due to the 

losses in the system. For instance ACOM2000A requires about 60W drive, therefore the 

transceiver should be able to put out 200 W for full output.     

2-3.  Mounting of the rack option  

W A R N I N G 

If you use the rack option, be sure to first place an amplifier on the lowest rack level in 
the following manner: 

Release the two drawer latches on the rear, pull out the drawer, place the amplifier on 
it, slide back the drawer and lock the two latches.  Afterwards, place the other two 
amplifiers in the same way. During an operation, all drawers must be locked and the 
wheel brakes engaged. 

2-4. Connections  

C A U T I O N  

We recommend you

 

use the supplied coaxial cables for the RF connections between the splitter / 

combiner and the amplifiers. If you have to use other coaxial cables, please note that the three 

coaxial cables going to the amplifier inputs should be the same length, as well as the three coaxial 

cables connected to the amplifier outputs. Any difference in lengths would cause a phase 

imbalance of the system thus excessive power loss and tripping of the protection circuit. 

 

Содержание 3x2000A

Страница 1: ...ACOM 3x2000A Outstanding HF Power Products HF POWER SPLITTER COMBINER FOR 3 AMPLIFIERS ...

Страница 2: ... 1 5 Safety Considerations Explicit Definitions 3 2 INSTALLATION 4 2 1 Unpacking and Initial Inspection 4 2 2 Preparing of the system units 4 2 3 Mounting of the rack option 4 2 4 Connections 4 3 OPERATION 7 4 MAINTENANCE 7 4 1 Cleaning 7 4 2 The ACOM3x2000A Simplified Schematic Diagram 8 4 3 Troubleshooting 8 5 SPECIFICATIONS 8 6 STORAGE AND SHIPMENT 8 ...

Страница 3: ... tuning indicator like ACOM1200 ACOM1000 ACOM1010 or ACOM1011 can be used too All these models use a broadband input network which sets minimum phase differences between the units An automatic protection circuit is implemented in the ACOM3x2000A which monitors the three amplifier outputs during operation In case of an imbalance the protection trips thus cutting the drive to the amplifiers and swit...

Страница 4: ...s with high RF voltages up to 1000V which can cause serious burns Do not open the device during the operation W A R N I N G HIGH VOLTAGE Never allow anyone ESPECIALLY CHILDREN to push anything into holes in the case this will cause electric shock NEVER TOUCH AN ANTENNA during transmission this may result in an electric shock or burn NEVER EXPOSE the splitter combiner to rain snow or any liquids AV...

Страница 5: ...mplifier for the needed output Add some overhead due to the losses in the system For instance ACOM2000A requires about 60W drive therefore the transceiver should be able to put out 200 W for full output 2 3 Mounting of the rack option W A R N I N G If you use the rack option be sure to first place an amplifier on the lowest rack level in the following manner Release the two drawer latches on the r...

Страница 6: ...utputs to the splitter combiner PA1 OUTPUT PA2 OUTPUT and PA3 OUTPUT receptacles B Connect the three supplied 1 5m RG58 coaxial cables with PL 259 plugs from the amplifiers inputs to the splitter combiner PA1 INPUT PA2 INPUT and PA3 INPUT receptacles C Connect the three supplied 1 5 m RCA connector cables from the amplifiers KEY IN sockets to the splitter combiner KEY IN 1 KEY IN 2 and KEY IN 3 so...

Страница 7: ...ect it to the KEY IN jack as shown on fig 2 3 Otherwise connect the supplied 3 m RCA cable from the transceiver socket providing ground on transmit to the splitter combiner KEY IN jack Transceiver producers give different names to this output and they are for instance TX GND SEND T R LINE AMPL etc Some transceivers require that ground on transmit is implemented via a software command or by changin...

Страница 8: ...tween 10 and 20 W continuous CW drive from the transceiver The tuning will be completed in few seconds and simultaneously the splitter combiner protection will trip Remove the drive power and press RESET button on the splitter combiner front panel Repeat the same steps successively on the second and the third amplifier The same procedure should be applied on every frequency segment antenna combina...

Страница 9: ...z continuously no tunings no switching maximum output mismatch up to 2 1 at reduced output see b above d Primary Power 100 240V via a 12V wallwart adapter supplied e Size Weight operating W210mm x D325mm x H195mm 6 4 kg f Operating environments temperature range 0 50 degs Celsius humidity up to 95 35 degs Celsius 6 STORAGE AND SHIPMENT C A U T I O N a Storage environments the splitter combiner can...

Отзывы: