User's Manual | ACOM 2020S | 1.8-54 MHz Linear Power Amplifier
June 2022
S e c t i o n INSTALLATION | Page 23 of 76
j)
RESET
button
Figure 2-6 | RCU model R05 rear panel
, Pos. (j).
In the unlikely event of RCU malfunction/freeze you can restart it by pressing
RESET
button for at least 3
seconds.
k)
Preparation of wall outlet
WARNING
Before connecting the amplifier to your mains supply using a licensed electrician, check
that the supply is correctly wired, and is adequate for the current drawn by the amplifier
(up to 20 A). Make certain that the grounding lead is connected properly and that it has
a cross section not less than the cross section of the phase conductor in the wall outlet
for the amplifier.
It is preferable that you use the wall outlet closest to the source. The installation leads should be at least
2.5 mm² (AWG 13 or SWG 15), recommended values if there are no stricter requirements by your local
standard.
Check that the panel fuse has a free capacity for the additional load from the amplifier as specified in
Section Specifications
8.1.h) Mains Power Consumption at Rated Output Power
. If you connect the amplifier to
a different mains outlet, be sure that you check it, too.
Make sure the main Power Switch (marked
ON
/
OFF
Figure 2-3 | Amplifier rear panel - Connections
Pos. (3), on the rear panel is in
OFF
position and insert amplifier's mains plug into the wall outlet prepared
for it. The amplifier remains switched off.