Acom 1200S Скачать руководство пользователя страница 9

88

 

 

    

 

   

 

 

 

 

              

 

                                                                                                                                                                                                                                                                             

The

 

transceiver

 

manufacturers

 

give

 

different

 

names

 

to

 

this

 

input,

 

for

 

example:

 

TX-INHIBIT,

 

MUTE,

 

LINEAR, and others. Check the manual of your transceiver. Approach your dealer for details. If your

 

transceiver

 

has

 

no

 

such

 

input,

 

do

 

not

 

worry

 

 

ACOM 700S

 

will

 

operate

 

normally

 

with

 

KEY-OUT

 

unconnected.

d)

 

RF

 

INPUT

 

-

 

Connect

 

a

 

coaxial

 

cable

 

with

 

a

 

PL-259

 

plug

 

from

 

the

 

transceiver

 

output

(antenna jack) to the amplifier RF INPUT jack.

C A U T I O N

In order to avoid at damage, turn off your transceiver’s internal antenna tuner.

e)

 

RF OUTPUT - Connect a suitable coaxial cable with a PL-259 plug from the RF OUTPUT

on

 

the

 

rear

 

amplifier

 

panel

 

to

 

the

 

antenna

 

switch,

 

tuner

 

or

 

antenna

 

intended

 

for

 

the

 

respective frequency band.

C A U T I O N

If you use

 

an

 

amplifier for the first time in your

 

shack, pay serious

attention

 

to

 

the

 

size

 

of

 

coaxial

 

cable

 

from

 

your

 

amplifier

 

output

to

 

the

 

antenna.

 

The

 

cable

 

must

 

be

 

capable

 

of

 

handling

 

the

increased power safely, particularly on the 10m and 6m bands.

This

 

warning

 

applies

 

equally

 

for

 

the

 

antenna

 

switch,

 

tuner,

 

and

the whole antenna system,

 

especially when using

 

multi-band

 

trap

 

antennas.

We recommend using RG213 or better. Consult your local coax cable supplier.

f)

 

Preparation of the mains outlet for the amplifier, requirements for the installation and

the mains voltage.

C A U T I O N

Before

 

connecting

 

your

 

amplifier

 

to

 

the

 

power

 

grid,

 

be

 

sure

that the

 

outlet

 

is correctly wired and is capable of providing the

required current

 

i.e.

 

(up to

 

10A from 200/240VAC mains and up to

16A from 100/120VAC mains). Also make sure that the grounding

lead is connected properly in the outlet,

 

intended for the amplifier.

If

 

subsequently

 

you

 

connect

 

the

 

amplifier

 

to

 

a

 

different

 

outlet,

check

 

it as well.

It is preferable to use the mains outlet closest to the source. Make sure that the respective fuses and

voltage, of your power mains match the ACOM 700S amplifier’s specifications (see S. 8-1(g)).

g)

 

Main fuses.

C A U T I O N

Make sure you check whether the main fuses installed in

your amplifier correspond to your local mains nominal voltage

and if necessary replace them as described in Section 7-2!

h)

 

Power

 

cord

 

inlet.

 

Due

 

to

 

different

 

mains

 

standards

 

in

 

different

 

countries,

 

the

ACOM 700S is delivered without a power plug for the mains cable. You dealer might

be able to provide the correct Safety Class I plug. The ground lead of the power cable

is colored yellow with two green stripes. If you have any doubts about the correct way

to connect these wires, consult your dealer.

Содержание 1200S

Страница 1: ...ACOM700S Outstanding HF Power Products HF 6 m LINEAR AMPLIFIER OPERATING MANUAL ...

Страница 2: ...3 6 Test transmission 13 4 AMPLIFIER OPERATION 16 4 1 Change of modes RX TX and Operate Stand by option AUTO OPERATE 16 4 2 Band change standard and expanded frequency coverage 17 4 3 Operation with an external antenna tuner 18 4 4 Automatic protection system 18 5 MENUS SETTINGS AND OPTIONS 19 5 1 Menu Measurements in the amplifier AMP MEASURE 20 5 2 Menu Service functions in the amplifier AMP SER...

Страница 3: ...2 2 ...

Страница 4: ...our local dealer first In the unlikely case of you needing further information you may get in touch with ACOM via fax 359 2 920 96 56 telephone 359 2 9209780 e mail acom acom bg com acom mail orbitel bg or by post blvd Nikola Mushanov 151 1330 Sofia Bulgaria Website www acom bg com 1 3 Equipment supplied and options The amplifier is supplied in a single box including amplifier ACOM 700S power cord...

Страница 5: ...tation receivers computers other amplifiers exceeding the standard EMC requirements due to the used PFC and built in radio frequency filters 1 5 Safety considerations explicit definitions The ACOM 700S linear amplifier is a Class I apparatus regarding protection against electric shock i e the third grounding lead of its mains cord colored yellow with two green stripes and the grounding stud on the...

Страница 6: ...nd theequipment connected to it Such repairs or changes arenot covered by the warranty and may void the warranty Themanufacturer is not liable for any such repairs or changes Any such repairs or changes are sole responsibility of theperson or persons engaging in them C A U T I O N To avoid damage not covered by the warranty please read the INSTALLATION Section 2 of this operating manual carefully ...

Страница 7: ... the amplifier in the shack W A R N I N G Before you connect the amplifier to external grounding you should advise with a licensed electrician and confirm such kind of connection is allowed by your national and local electrical code safety rules and regulations in force Simultaneous connection to the earth grounding and protective earth may be inadmissible or may fall under special requirements in...

Страница 8: ...ck does not exceed 12V and the current is below 6mA See also S 8 2 a N O T E Your amplifier will not work if the KEY IN input is not connected correctly If you experience any difficulty consult your dealer Fig 2 1 Rear panel connections c KEY OUT jack transmit enabling control output from amplifier to the transceiver The KEY OUT jack on the rear panel provides an extra control signal from the ampl...

Страница 9: ... better Consult your local coax cable supplier f Preparation of the mains outlet for the amplifier requirements for the installation and the mains voltage C A U T I O N Before connecting your amplifier to the power grid be sure that the outlet is correctly wired and is capable of providing the required current i e up to 10A from 200 240VAC mains and up to 16A from 100 120VAC mains Also make sure t...

Страница 10: ...e an exact frequency data but only band data Those connections cannot be used when ACOM 700S works together with ACOM 04AT because the tuner needs to know the exact frequency not the band Table 2 1 shows the signals and the pin out of the CAT AUX connector rear panel of the amplifier Table 2 1 CAT AUX interface PIN NO PIN NAME DESCRIPTION SPECIFICATIONS Rear panel view 1 RxD Received Data TTL inpu...

Страница 11: ...east 4 hours A similar effect could occur following a rapid warming of the room such as winter usage of a powerful electric heater After following all instructions in Section 2 INSTALLATION check whether the rear panel mains switch is turned off Then plug the amplifier in the mains outlet 3 1 Low energy standby mode of the power supply Now you can turn on the mains switch on the rear panel This wi...

Отзывы: