Acom 1200S Скачать руководство пользователя страница 7

66

N O T E

Keep the original packing for possible future transportation. 

Unpack and inspect carefully the contents of the cardboard carton for possible transportation damages. 

On the amplifier, check-up the chassis, front panel, display, buttons, rear panel connectors, main power 

switch and fuses.

2-2. 

Amplifier operating location selection; cooling.

Locate the amplifier close to the place where will be used. You will need an easy access to the rear panel 

for connecting cables, and of course, to the buttons and screen on the front panel.

The ACOM 700S is forced air cooled.  Locate the amplifier so that there are no objects or other devices 

closer  than  10cm  (4”). The  exhaust  air  can  reach  65ºC  (150ºF)  and  if  the  surrounding  devices  are 

sensitive to heating from outside or use forced air cooling themselves, increase the distances accordingly.

C A U T I O N

Do not leave free paper, cloth or other light materials around 

and under  the  amplifier. They  may  be  drawn  in  by  the  cooling 

air stream and block the vents. This will lead to overheating and 

accelerated material aging, not covered by the warranty.

2-3. 

Connecting the amplifier in the shack

W A R N I N G

Before  you  connect  the  amplifier  to  external  grounding, 

you should advise with a licensed electrician and  confirm 

such  kind  of  connection  is  allowed  by  your  national and 

local electrical code, safety rules, and regulations in force. 

Simultaneous connection to the  earth  grounding  and 

protective earth  may  be  inadmissible  or  may  fall  under 

special requirements in some countries!

W A R N I N G

Never use the gas installation pipes for grounding. This can 

cause an EXPLOSION!

W A R N I N G

Do not use the steam-heating or water-supply network pipes 

for grounding! You may expose to dangerous voltage not only 

yourself but also other people using the same installation.

C A U T I O N

Bear in mind that the grounding installation may have to withstand 

emergency  currents  over 15A with minimal voltage drop on it. 

Therefore it may be necessary to improve its conductivity using 

heavier leads and lower-resistance grounding path.The grounding 

lead should be at least 4mm

2

 (AWG 11 or SWG 13).

For details and recommendations on the grounding and RF counterpoise system concerning the 

electromagnetic compatibility see also S. 3-6(f).

a)  GND stud - First connect the grounding stud of the amplifier (located on the rear panel and 

marked GND – Fig. 2-1) to the grounding system of the shack.

Содержание 1200S

Страница 1: ...ACOM700S Outstanding HF Power Products HF 6 m LINEAR AMPLIFIER OPERATING MANUAL ...

Страница 2: ...3 6 Test transmission 13 4 AMPLIFIER OPERATION 16 4 1 Change of modes RX TX and Operate Stand by option AUTO OPERATE 16 4 2 Band change standard and expanded frequency coverage 17 4 3 Operation with an external antenna tuner 18 4 4 Automatic protection system 18 5 MENUS SETTINGS AND OPTIONS 19 5 1 Menu Measurements in the amplifier AMP MEASURE 20 5 2 Menu Service functions in the amplifier AMP SER...

Страница 3: ...2 2 ...

Страница 4: ...our local dealer first In the unlikely case of you needing further information you may get in touch with ACOM via fax 359 2 920 96 56 telephone 359 2 9209780 e mail acom acom bg com acom mail orbitel bg or by post blvd Nikola Mushanov 151 1330 Sofia Bulgaria Website www acom bg com 1 3 Equipment supplied and options The amplifier is supplied in a single box including amplifier ACOM 700S power cord...

Страница 5: ...tation receivers computers other amplifiers exceeding the standard EMC requirements due to the used PFC and built in radio frequency filters 1 5 Safety considerations explicit definitions The ACOM 700S linear amplifier is a Class I apparatus regarding protection against electric shock i e the third grounding lead of its mains cord colored yellow with two green stripes and the grounding stud on the...

Страница 6: ...nd theequipment connected to it Such repairs or changes arenot covered by the warranty and may void the warranty Themanufacturer is not liable for any such repairs or changes Any such repairs or changes are sole responsibility of theperson or persons engaging in them C A U T I O N To avoid damage not covered by the warranty please read the INSTALLATION Section 2 of this operating manual carefully ...

Страница 7: ... the amplifier in the shack W A R N I N G Before you connect the amplifier to external grounding you should advise with a licensed electrician and confirm such kind of connection is allowed by your national and local electrical code safety rules and regulations in force Simultaneous connection to the earth grounding and protective earth may be inadmissible or may fall under special requirements in...

Страница 8: ...ck does not exceed 12V and the current is below 6mA See also S 8 2 a N O T E Your amplifier will not work if the KEY IN input is not connected correctly If you experience any difficulty consult your dealer Fig 2 1 Rear panel connections c KEY OUT jack transmit enabling control output from amplifier to the transceiver The KEY OUT jack on the rear panel provides an extra control signal from the ampl...

Страница 9: ... better Consult your local coax cable supplier f Preparation of the mains outlet for the amplifier requirements for the installation and the mains voltage C A U T I O N Before connecting your amplifier to the power grid be sure that the outlet is correctly wired and is capable of providing the required current i e up to 10A from 200 240VAC mains and up to 16A from 100 120VAC mains Also make sure t...

Страница 10: ...e an exact frequency data but only band data Those connections cannot be used when ACOM 700S works together with ACOM 04AT because the tuner needs to know the exact frequency not the band Table 2 1 shows the signals and the pin out of the CAT AUX connector rear panel of the amplifier Table 2 1 CAT AUX interface PIN NO PIN NAME DESCRIPTION SPECIFICATIONS Rear panel view 1 RxD Received Data TTL inpu...

Страница 11: ...east 4 hours A similar effect could occur following a rapid warming of the room such as winter usage of a powerful electric heater After following all instructions in Section 2 INSTALLATION check whether the rear panel mains switch is turned off Then plug the amplifier in the mains outlet 3 1 Low energy standby mode of the power supply Now you can turn on the mains switch on the rear panel This wi...

Отзывы: