Arrange the following cables in their maximum lengths to the panel: 

 

2 wires x 1mm

2

 - power supply 

 

2 wires x 0.75mm

2

 - to E-lock 

 

UTP (standard T568B) - bus, max. 70m - from the panel (or the last power supply unit), 300m in total - when using 
additional power supplies. 

If cross-sections are smaller and connections that are too long, voltage drops may occur, causing the panel to malfunction. 
To extend the length of cables, their cross-section must be increased. 

 

WIRING DIAGRAM 

 

 

Note! 

 

If the system features only one monitor, no video splitter is necessary 
and  the  monitor  is  connected  at  the  end  of  the  UTP  bus  leaving  the 
panel.  It  is  then  absolutely  necessary  to  connect  the  monitor  power 
supply  by  connecting  the  bus  cable:  orange  and  brown  together  to 
"+DC"  terminal  of  the  panel  (in  this  case  the  maximum  distance 
between the panel and the monitor is 70m). When using Video splitters, 
cable length may be extended up of 300m from the panel to the monitor, 
assuming that the splitter, with a  power supply 

A

 to it - is within 70m 

from  the  monitor.  (It  is  then  not  required  to  connect  the  orange  and 
brown wires to the panel - 

it’ enough to use jumper J1 on the splitter). 

 

MONITOR INSTALLATION AND CONNECTION 

 

When installing the monitor refer to the user instruction delivered with the monitor. 

 

When connecting the monitor, make sure the RJ45 plug (standard T568B) is crimped. Before turning on the power, make sure that 
all RJ45 plugs are properly crimped (the same way), that the wires conduct current and check for possible short circuits between the 
wires. If even one RJ connector is badly crimped or in case of a short circuit between wires, the video inside unit, splitter or combiner 
may be damaged. 

 

Note! 

Also make sure that addresses are properly configured in the monitor. For panels with direct

 

call buttons (ring buttons), button 

addresses are pre-set from 1 to 6 (depending on panel model). The lowest button corresponds to address 1. If no direct button is 
present buttons, the addresses of the monitors are called directly from the numeric keypad (pre-set at 1 to 10). 

 

There may be monitors with the same addresses in the video system, which means that several monitors can call at the same time 
when the call button is pressed. If have an additional indoor units, calling simultaneously with the monitor, use INS-UP720MR, UP800 
indoor units. Use INS-UP720MR, UP800 indoor units also when only one indoor unit needs to be installed to call upon pressing the 
call button. 

 

INPUT 

VS 

VIDEO 

LINE 

INPUT 

ELOCK 

-DC 

POWER 

+DC 

POWER 

GND 

max 1A 

Power 

15 V DC 

ROZDZIELACZ 

/ SPLITTER 

ML 

1 Orange and white 
2 Orange 
3 Green and white 
4 Blue 
5 Blue and white 
6 Green 
7 Brown and white 
8 Brown 

Power supply 

Video 

- Signal line (GND) 

Power supply 

+ Signal line (L+) 

ON 

Address: 1 

Address: 2 

Address: 3 

Address: 46 

ON 

ON 

ON 

CODE/ADDRESS 

CODE/ADDRESS 

CODE/ADDRESS 

CODE/ADDRESS 

ON 

OFF 