background image

For safe and proper use, always carefully read through the 
instructions for use and all other documents enclosed with the 
product, pass them on to the end user and keep them until the 
end of the product‘s life.

ACO Self® Europoint 
installation instructions

Europoint Flat

Europoint Deep/Round

Europoint Deep

1

Содержание 319601

Страница 1: ...the instructions for use and all other documents enclosed with the product pass them on to the end user and keep them until the end of the product s life ACO Self Europoint installation instructions...

Страница 2: ...ice spare parts and accessories Spare parts and accessories refer to Product catalogue http www aco hochbau de products For additional information http www aco hochbau de kontakt Warranty For informat...

Страница 3: ...1 6 Disposal 6 2 Product Description 6 2 1 Product features 6 2 2 Accessories 6 2 3 ACO Self Construction Kit 7 3 Installation 8 3 1 Connection to the pipework 8 3 2 ACO Self Europoint Flat 8 3 3 ACO...

Страница 4: ...lation and utilisation possibilities as well as alterations are prohibited 1 2 Personnel qualifications References to other information in these assembly instructions for use and other documents 1 For...

Страница 5: ...tor Mortar bucket Trowel Figure Meaning Safety footwear provides good slip resistance especially in wet conditions as well as a high degree of penetration resistance e g in case of nails and protects...

Страница 6: ...scription 1 5 Cleaning 2 1 Product features Features of the ACO Self Europoint Manufactured according to DIN 1236 EN124 drive on capable for passenger cars up to Class B Sockets as vertical horizontal...

Страница 7: ...optional Top chamber optional Intermediate section Outlet Top chamber With downpipe connection with DN 100 lip labyrinth seal Art No 319607 Flat drain body with socket for connection of DN OD 110 KG p...

Страница 8: ...Installation situation Garden Patio or Terraces Product s ACO Self Europoint Flat IMPORTANT Always clean the gully before installation to ensure the function Installation suggestion for ACO Self Europ...

Страница 9: ...0 mm for vertical standard point connection Compact the substrate with sand bedding material as sand 0 8 Install point outlet Grease the socket 1 Attach Europoint Flat with grating and align approx 3...

Страница 10: ...ep IMPORTANT Always clean the gully before installation to ensure the function Installation suggestion for ACO Self Europoint 1 Grating 2 ACO Self Europoint Deep 3 KG pipe 4 Foundation concrete 5 Conc...

Страница 11: ...x 0 5 m x 1 0 m Increase the installation space accor dingly when utilising a top chamber KG pipe socket 110 mm for Euro point horizontal connection Install point outlet Create the foundation Foundat...

Страница 12: ...must be connected before filling with bed ding material when utilising the top chamber 3 Seal the top frame with ACO Water seal if necessary Insert frame with grating 4 approx 3 5 mm below adjacent s...

Страница 13: ...e the function Installation suggestion for ACO Self Europoint Deep Round 3 3 ACO Self Europoint Deep Round 1 Grating 2 Top chamber 3 ACO Self Europoint Deep Round 4 KG pipe 5 Foundation concrete 6 Con...

Страница 14: ...77 mm Two intermediate parts 554 mm KG pipe collar 110 mm for Euro point horizontal connection Installation space dimensions Without intermediate section 553 528 mm One intermediate section 830 805 mm...

Страница 15: ...rt Adjust the top part to the surface by turning tilting or height adjustment Seal intermediate part with ACO Waterseal if necessary Insert frame with grating approx 3 5 mm below adjacent surface e g...

Страница 16: ...art to the surface by turning tilting or height adjustment Seal intermediate part with ACO Waterseal if necessary Insert frame with grating approx 3 5 mm below adjacent surface e g paviors When utilis...

Страница 17: ...17 Installation max 60 mm Fill in with concrete to maximum 60 mm below surface Foundation concrete quality minimum C12 15 Lay the paviors wet in wet...

Страница 18: ...metal the design frame can be fitted on the edge of the Europoint The frame has 2 different heights and will be adapted to the grating height 3 51 Installing the ACO Self Europoint Deep Round Height...

Страница 19: ...gn frame into place at 4 external snap in points Once installed design frames cannot be dismantled again The design frame is correctly fitted on when the grating and frame edge are the same height Upp...

Страница 20: ...lean more regularly in the case of a high degree of soiling e g by falling leaves Always remove dirt and foreign bodies Inspect for unobstructed inlets and outlets Replace missing or defective parts 2...

Страница 21: ...21 Cleaning the ACO Self Europoint Insert odour trap leaf trap sludge bucket and grating...

Страница 22: ...22 Notice 5 Notice These pages are available for handwritten notes e g details for the products utilised...

Страница 23: ...23 Notice...

Страница 24: ...1 Bad Kissingen Germany Neuwirtshauser Stra e 14 97723 Oberthulba Germany Tel 09736 41 60 Fax 09736 41 69 ACO Hochbau Vertrieb GmbH ACO creating the future of drainage MA5292_V1 0_DE LTC 1014 Issued 2...

Отзывы: