15. Zoom Error
Check whether the position of the zoom where the magnet is installed falls off or is damaged.
Check whether there are obstacles in the zoom operating range.
Check whether the Hall element on the zoom is damaged.
Check whether the lead connecting the Hall element on the zoom and the PCB board is in poor
contact or disconnected.
Check whether the motor on the zoom is damaged.
Check whether the related circuit of the motor drive board on the zoom is damage.
16. Blade Reset Error
Check whether the position of the blade where the magnet is installed falls off or is damaged.
Check whether there are obstacles in the blade operating range.
Check whether the Hall element on the blade is damaged.
Check whether the lead connecting the Hall element on the blade and the PCB board is in poor
contact or disconnected.
Check whether the motor on the blade is damaged.
Check whether the related circuit of the motor drive board on the blade is damage.
The position of each fan of the fixture: