background image

 
 

6. Control By Universal DMX Controller   
6.1 DMX512 Connection   

 

 

 

1.  At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W 
resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output 
of the last unit. 
2.  Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to 
the input of the next unit. The cable cannot be branched or split to a “Y” cable. DMX 512 is a very 
high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily 
distort the signal and shut down the system. 
3.  The DMX output and input connectors are pass-through to maintain the DMX circuit, when one 
of the units’ power is disconnected. 
4.  Each lighting unit needs to have a DMX address to receive the data by the controller. The 
address number is between 1-512. 
5.  The end of the DMX 512 system should be terminated to reduce signal errors. 
6.  3 pin XLR connectors are more popular than 5 pins XLR. 

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used. 

 

22D 

Содержание SolarFlare

Страница 1: ......

Страница 2: ... 4 Effect Wheels 9 5 How To Set The Unit 9 5 1 Main Function 9 5 2 Home Position Adjustment 17 6 Control By Universal DMX Controller 22 6 1 DMX512 Connection 22 6 2 Address Setting 23 6 3 DMX512 Configuration 23 7 Error Information 28 8 Troubleshooting 32 9 Fixture Cleaning 32 1D ...

Страница 3: ...ion slots is blocked otherwise the unit will be overheated Before operation ensure that you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product s specification label It s important to ground the yellow green conductor to earth in order to avoid electric shock Minimum ambient temperature TA 0 Maximum ambient temperature TA 40 Do n...

Страница 4: ...r malfunction Please contact the nearest authorized technical assistance center if needed Disconnect this product from its power source before servicing DO use the original packaging if the device is to be transported Avoid direct eye exposure to the light source while the product is on DO NOT operate this product if you see damage on the housing shields or cables Have the damaged parts replaced b...

Страница 5: ...ulez l appareil en portant sa base au lieu de la tête uniquement L unité doit être installée dans un endroit avec une ventilation adéquate à au moins 50cm des surfaces adjacentes Assurez vous qu aucune fente d aération du luminaire n est obstruée sinon il risque de surchauffer Avant toute utilisation assurez vous que vous connectez ce luminaire à la tension appropriée conformément aux spécificatio...

Страница 6: ...rêtez immédiatement d utiliser l appareil N allumez et n éteignez jamais ce luminaire à maintes reprises Le boîtier les lentilles ou le filtre ultraviolet doivent être remplacés s ils sont visiblement endommagés NE PAS ouvrir le boîtier car il ne contient aucune pièce réparable par l utilisateur NE PAS mettre ce luminaire en fonctionnement s il est endommagé N effectuez pas de réparations vous mêm...

Страница 7: ...er au moins 12 fois le poids du luminaire lors de l installation L installation et l utilisation de ce luminaire doit être effectué par un opérateur qualifié Il doit être installé dans un endroit hors de portée des personnes 2 Technical Specifications Power Voltage 100 240V 50 60Hz Power Consumption 1535W Light Source SSL1050AC Color Temperature 6500K Zoom Range 5 72 Movement Pan 540 Tilt 270 Pan ...

Страница 8: ... 90 Switch to high CRI mode with high CRI filter Linear CMY color mixing Variable CTO The patented design frost filters made of brand new material can achieve 0 100 linear softening and make the spot larger and more uniform 4 x fast and smooth framing shutters the position and the angel of each shutter blade can be controlled individually the framing module can be rotated at 45 degrees 2 x fixed cl...

Страница 9: ...rform the desired functions 3 BATTERY DISPLAY 4 ETHERNET Transfers fixture s information to a main controller 4 DMX IN For DMX512 operation use 3 5 pin XLR cable to link the unit and DMX controller 5 DMX OUT For DMX512 operation use 3 5 pin XLR cable to link the next units 7 POWERCON IN To connect to supply power 8 POWERCON OUT To connect to the next fixture 9 POWER SWITCH Turns on off the power 1...

Страница 10: ...ess the MENU button into menu mode and press the UP DOWN button until the required function is shown on the monitor Select the function by pressing the ENTER button Use the UP DOWN button to choose the submenu press the ENTER button to store and automatically return to the last menu Press the MENU button or let the unit idle 30 seconds to exit menu mode The main functions are shown below 9D ...

Страница 11: ...10D ...

Страница 12: ...tton back to the last menu or let the unit idle 30 seconds to exit menu mode DMX Channel Mode To select DMX Channel Mode press the ENTER button to confirm Use the UP DOWN button to select 27 F Wash or 18 Wash press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Connect Option To select Connect Option press the ENTER button to...

Страница 13: ... the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode sACN To select sACN press the ENTER button to confirm Use the UP DOWN button to select Universe or Priority press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Repeat On DMX To select Repeat On DMX press the ENTER button to confirm Use t...

Страница 14: ...to the last menu or let the unit idle 30 seconds to exit menu mode Dimmer Speed To select Dimmer Speed press the ENTER button to confirm Use the DOWN UP button to select Fast or Smooth press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Dimmer Curve To select Dimmer Curve press the ENTER button to confirm Use the DOWN UP but...

Страница 15: ... will blink on the display use the UP DOWN button to select No normal display or Yes invert display press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Backlight Intensity Select Backlight Intensity press the ENTER button to confirm present mode will blink on the display use the UP DOWN button to adjust value from 1 to 10 pr...

Страница 16: ...g Manual Mode menu Fixture Information To select Fixture Information press the ENTER button to confirm use the UP DOWN button to select Fixture Use Hour Temperature Fan State Voltage Upgrade Files or Firmware Version Fixture Use Hour Select Fixture Use Hour press the ENTER button to confirm fixture use hour will show on the display press the MENU button to exit Temperature Select Temperature press...

Страница 17: ...U button to exit Effect Reset Select Effect Reset press the ENTER button to confirm use the UP DOWN button to select No or Yes the unit will run built in program to reset effect to their home positions press the ENTER button to store Press the MENU button to exit All Reset Select All Reset press the ENTER button to confirm use the UP DOWN button to select No or Yes the unit will run built in progr...

Страница 18: ...he fixture Select the DEVICE HOURS menu to display the running time of the fixture Select the PAN INVERT menu and the fixture will run the pan invert mode Select the TILT INVERT menu and the fixture will run the tilt invert mode Select the RESET DEVICE menu the WARM RESET COLD RESET option will be displayed When WARM RESET is selected the fixture will start a warm reset and exit when COLD RESET is...

Страница 19: ...ode Select Dimming Start press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 0 to 9999 press the ENTER button to store Press the MENU button to exit 18D ...

Страница 20: ...button to offset the value from 128 to 127 press the ENTER button to store Press the MENU button to exit Magenta Enter offset mode Select Magenta press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 128 to 127 press the ENTER button to store Press the MENU button to exit Yellow Enter offset mode Select Yellow press the ENT...

Страница 21: ...offset the value from 128 to 127 press the ENTER button to store Press the MENU button to exit BladeDW1 Enter offset mode Select BladeDW1 press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 0 to 255 press the ENTER button to store Press the MENU button to exit BladeDW2 Enter offset mode Select BladeDW2 press the ENTER but...

Страница 22: ...t mode Select BladeRG1 press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 0 to 255 press the ENTER button to store Press the MENU button to exit BladeRG2 Enter offset mode Select BladeRG2 press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 0 to ...

Страница 23: ...signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Each lighting unit needs to have a DMX address to receive the data by the controller The address number is between 1 512 5 The end of the DMX...

Страница 24: ...seconds to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 27 channels 1 28 55 82 18 channels 1 19 37 55 6 3 DMX512 Configuration Please control the fixture by referring to the configurations below Attentions 1 The unit will maintain the last condition until reset if y...

Страница 25: ...8 036 037 045 046 054 055 063 064 127 128 189 190 193 194 255 Color 2 Open Color1 Color2 Color3 Color4 Color5 Color6 Color Index Rotate Fast to Slow Stop Rotate Slow to Fast 12 000 007 008 255 CRI Close Open 13 000 255 Frost 0 100 14 000 255 Zoom 72 5 15 000 007 008 015 016 131 132 139 140 181 182 189 190 231 232 239 240 247 248 255 Strobe Close Open Strobe Slow to Fast Open Fast Open Slow Close O...

Страница 26: ... 030 039 040 049 050 059 060 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 179 180 189 190 199 200 209 210 219 220 229 230 255 Function Null Dimmer Curve Square Law Dimmer Curve INV Square Law Dimmer Curve Linear Dimmer Curve S Soften Mode On Soften Mode Off Null LED Frequency Setting Enable LED Frequency Setting Disable Null Null Null Null Null Null Dimme...

Страница 27: ... 255 CTO 0 100 10 000 009 010 018 019 027 028 036 037 045 046 063 064 127 128 189 190 193 194 255 Color 1 Open Color1 Color2 Color3 Color4 Color5 Color Index Rotate Fast to Slow Stop Rotate Slow to Fast 11 000 009 010 018 019 027 028 036 037 045 046 054 055 063 064 127 128 189 190 193 194 255 Color 2 Open Color1 Color2 Color3 Color4 Color5 Color6 Color Index Rotate Fast to Slow Stop Rotate Slow to...

Страница 28: ...r Fine 18 000 029 030 039 040 049 050 059 060 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 179 180 189 190 199 200 209 210 219 220 229 230 255 Function Null Dimmer Curve Square Law Dimmer Curve INV Square Law Dimmer Curve Linear Dimmer Curve S Soften Mode On Soften Mode Off Null LED Frequency Setting Enable LED Frequency Setting Disable Null Null Null Nul...

Страница 29: ...amaged Check whether the related circuit of the motor drive board on the pan is damage 3 Pan Encoder Error Check whether the encoder on the pan is damaged Check whether the lead connecting the encoder on the pan and the PCB board is in poor contact or disconnected 4 Tilt Reset Error Check whether the position of the tilt where the magnet is installed falls off or is damaged Check whether there are...

Страница 30: ... Cyan Error Check whether the position of the cyan color wheel where the magnet is installed falls off or is damaged Check whether there are obstacles in the cyan color wheel operating range Check whether the Hall element on the cyan color wheel is damaged Check whether the lead connecting the Hall element on the cyan color wheel and the PCB board is in poor contact or disconnected Check whether t...

Страница 31: ...f the cto where the magnet is installed falls off or is damaged Check whether there are obstacles in the cto operating range Check whether the Hall element on the cto is damaged Check whether the lead connecting the Hall element on the cto and the PCB board is in poor contact or disconnected Check whether the motor on the cto is damaged Check whether the related circuit of the motor drive board on...

Страница 32: ...ether the related circuit of the motor drive board on the zoom is damage 16 Blade Reset Error Check whether the position of the blade where the magnet is installed falls off or is damaged Check whether there are obstacles in the blade operating range Check whether the Hall element on the blade is damaged Check whether the lead connecting the Hall element on the blade and the PCB board is in poor c...

Страница 33: ...ith the signal circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB might be broken 2 The motor s drive IC on the PCB might be out of condition 9 Fixture Cleaning It is absolutely essential that the fixture is kept clean to ensure the maximum light output and allow the fixture to function reliably throughout its life The fixture m...

Страница 34: ...33D ...

Страница 35: ...sion of the Electromagnetic Compatibility EMC Directive 2014 30 EU EN 55032 2015 EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 55035 2017 Harmonized Standard EN 60598 1 2015 A1 2018 EN 60598 2 17 2018 EN 62493 2015 Safety of household and similar electrical appliances Part 1 General requirements and tests Certifications cETLus Approved Control 5000057 34D ...

Страница 36: ...Innovation Quality Performance ...

Отзывы: