The EBSM Motor is an integrated industrial motor and speed 

control that is simple and easy to install.

General Safety Information

This equipment contains voltages that may be as high as 1000 volts! 

Electrical  shock  can  cause  serious  or  fatal  injury.  Only  qualified 

personnel should attempt the start-up procedure or troubleshoot 

this equipment.
This equipment may be connected to other machines that have 

rotating parts or parts that are driven by this equipment.  Improper 

use can cause serious or fatal injury. Only qualified personnel should 

attempt the start-up procedure or troubleshoot this equipment.

WARNING:

 Do not touch any circuit board, power device or 

electrical connection before you first ensure that power has been 

disconnected.  Electrical shock can cause serious or fatal injury. 

Only qualified personnel should attempt the installation, operation 

and maintenance of this equipment.

WARNING:

 Disconnect all electrical power from the motor windings 

and accessory devices before disassembly of the motor. Electrical 

shock can cause serious or fatal injury.

WARNING:

 Be sure the system is properly grounded before 

applying power. Do not apply AC power before you ensure that 

all grounding instructions have been followed. Electrical shock can 

cause serious or fatal injury.  National Electrical Code and Local 

codes must be carefully followed.

WARNING:

 Avoid extended exposure to machinery with high noise 

levels. Be sure to wear ear protective devices to reduce harmful 

effects to your hearing.  

WARNING:

 Surface temperatures of motor may reach temperatures 

which can cause discomfort or injury to personnel accidentally 

coming into contact with hot surfaces. When installing, protection 

should be provided by the user to protect against accidental contact 

with hot surfaces. Failure to observe this precaution could result in 

bodily injury.

WARNING:

 Always disconnect, lock and tag power source before 

installing or servicing. Failure to disconnect power source can 

result in fire, shock or serious injury.

WARNING:

  Motors  that  are  to  be  used  in  flammable  and/or 

explosive atmospheres must display the CSA listed logo. Specific 

service conditions for these motors are defined in NFPA 70 (NEC) 

Article 500.

WARNING:

 Pacemaker danger – Magnetic and electromagnetic 

fields in the vicinity of current carrying conductors and permanent 

magnet motors can result in a serious health hazard to persons 

with cardiac pacemakers, metal implants, and hearing aids. To 

avoid risk, stay way from the area surrounding a permanent magnet 

motor.

WARNING:

  Do  not  remove  cover  for  at  least  five  (5)  minutes 

after AC power is disconnected to allow capacitors to discharge. 

Dangerous voltages are present inside the equipment.  Electrical 

shock can cause serious or fatal injury.

WARNING:

 Motor circuit may have high voltage present whenever 

AC power is applied, even when motor is not rotating. Electrical 

shock can cause serious or fatal injury.

CAUTION:

  Disconnect motor leads (T1, T2 and T3) from control 

before you perform a dielectric withstand (insulation) test on the 

motor.  Failure to disconnect motor from the control will result 

in extensive damage to the control. The control is tested at the 

factory for high voltage / leakage resistance as part of Underwriter 

Laboratory requirements.

CAUTION:

  Suitable for use on a circuit capable of delivering not 

more than 5000 RMS symmetrical short circuit amperes at rated 

voltage.

CAUTION:

  Connection of power 115 or 230VAC power to “N” will 

damage the unit.

1. Follow all local electrical and safety codes, as well as 

the National Electrical Code (NEC) and the National Fire 

Protection Agency (NFPA), where applicable. Follow the 

Canadian Electric Code (CEC) in Canada.

2.  The rotation of the fan wheel is critical. It must be free to 

rotate without striking or rubbing any stationary objects.

3.  Motor must be securely and adequately grounded.

4. Do not spin fan wheel faster than max cataloged fan 

RPM. Adjustments to fan speed significantly effects motor 

load. If the fan RPM is changed, the motor current should 

be checked to make sure it is not exceeding the motor 

nameplate amps.

5.  Do not allow the power or speed control cables to kink or 

come in contact with oil, grease, hot surfaces or chemicals. 

If damaged, discontinue use immediately and have cord 

replaced.

6. Verify that the power source is compatible with the 

equipment. Branch protection and disconnect means must 

be provided if required.

7.  Never open access doors to a duct while the fan is running.

Features

Soft Start

All EBSM motors use soft start motor technology.  They will reliably 

start at any speed setting.  

Overload

If the motor becomes overloaded, the control begins a countdown 

that creates an “Overload fault” when it ends.

Locked Rotor Protection

If a locked rotor condition occurs, the motor will automatically shut 

itself down. Restart is attempted (up to 3 times). If the 3rd attempt is 

unsuccessful, the motor will not attempt restart until power is cycled 

(turned “Off” then “On”).

This section applies only to Baldor EC Motor 2 HP

5

Содержание PVD EC

Страница 1: ...d methods that will not cause damage Fans should be lifted using slings and padding or spreaders to avoid damage CAUTION Always make sure that all lifting and handling equipment and techniques conform...

Страница 2: ...oisture or dirt accumulations are found on parts the source should be located and eliminated Fans should be rotated at each inspection by hand ten to fifteen revolutions to redistribute the motor and...

Страница 3: ...into the wheel MAINTENANCE 1 Under normal usage no spare parts are recommended for one year of operation Recommended spare parts are shown on page 4 2 CAUTION Before proceeding make sure electrical s...

Страница 4: ...is product may be installed on a wooden metal or concrete deck following the requirements shown in Figure 1 The matching curb of Model CH for this particular use must be used It is the installers resp...

Страница 5: ...d electromagnetic fields in the vicinity of current carrying conductors and permanent magnet motors can result in a serious health hazard to persons with cardiac pacemakers metal implants and hearing...

Страница 6: ...otations Rotation can be changed by swapping any of the Red Black and Blue wires connecting the control board to the motor at terminals T1 T2 and T3 Installation 1 Wire motor in accordance with local...

Страница 7: ...e switch and mounting plate fit in a standard gang box and wired to Dual Potentiometer Speed Dial The speed dial can be mounted up to 100 ft from fan using additional wire by others Building Control 0...

Страница 8: ...tain that they are secure Fault Indication A red LED on the control board provides fault indication During a fault this LED will blink a specific number of times to identify the fault that has occurre...

Страница 9: ...ontrol cable and quick connect Molex plug that can be plugged into the Molex plug on dual speed dial The supplied unmounted toggle switch will select the Low LO or High HI speed on the speed controlle...

Страница 10: ...10 FIGURE 7 PerfectSpeed Control Cable FIGURE 7A Remote Potentiometer A Variable 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Speed B Potentiometers and or speed select switch mounted up to 100 ft from...

Страница 11: ...ack Red White Wired in Field Red to Red White to White Black to Black A Variable 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Speed B B Potentiometers and or speed select switch mounted up to 100 ft from...

Страница 12: ...to discharge any residual voltage 2 Check the rotation and speed of the motor Determine if the motor can spin freely by hand without effort or assisted means If any binding occurs replace the motor an...

Страница 13: ...Bracket 6 2 Hood Fastener 3 8 Disconnect Switch 1 3 Windband 1 9 Support Side Birdscreen 2 4 Motor 1 10 Wheel 1 5 Separator Plate 2 11 Conduit 1 6 Motor Base 1 12 Curb Base and Orifice 1 PVD Exploded...

Страница 14: ...y claim the Company shall have the option either to inspect the product while in Purchaser s possession or to request Purchaser to return the product to the Company at Purchaser s expense for inspecti...

Отзывы: