ACME MH-575S Скачать руководство пользователя страница 8

 

14- 

   

Firmware version 

Press  the 

MENU

  button  up  to  when  the 

 

is  blinking  on  the  display.  Pressing 

ENTER

 button and the display will show the firmware version of the unit. To go back to the 

functions press the

 MENU

 button again. 

   

Reset 

Press  the 

MENU

  button  up  to  when  the 

 

is  blinking  on  the  display.  Pressing 

ENTER

 button and all channels of the unit will return to their standard position. To go back 

to the functions press the

 MENU

 button again.

 

DMX RESET

 : 

Set DMX value of channel 13 between 200 to 255, then all channels of the unit will return to 

their standard home position.   

 

  4.3 Home Position Adjustment   

Press 

MENU 

button for at least 5 seconds into offset mode to adjust the home position. 

 

    Pan offset 

Press the 

MENU

 button for at least 5 seconds into offset mode, use 

DOWN

 and 

UP

 button 

up to when the 

  is shown on the display. Pressing 

ENTER

 button and the display 

will blink. Use 

DOWN

 and 

UP

 button to adjust the pan home position. Once the position has 

been  selected,  press  the 

ENTER

  button  to  setup  or  automatically  return  to  the  offset 

functions  without  any  change  press  the 

MENU

  button  again,  To  go  back  to  the  main 

 

15- 

functions without any change after 8 seconds. 

    Tilt offset 

Press the 

MENU

 button for at least 5 seconds into offset mode, use 

DOWN

 and 

UP

 button 

up to when the 

  is shown on the display. Pressing 

ENTER

 button and the display 

will blink. Use 

DOWN

 and 

UP

 button to adjust the tilt home position. Once the position has 

been  selected,  press  the 

ENTER

  button  to  setup  or  automatically  return  to  the  offset 

functions  without  any  change  press  the 

MENU

  button  again,  To  go  back  to  the  main 

functions without any change after 8 seconds. 

    Color offset 

Press the 

MENU

 button for at least 5 seconds into offset mode, use 

DOWN

 and 

UP

 button 

up to when the 

  is shown on the display. Pressing 

ENTER

 button and the display 

will blink. Use 

DOWN

 and 

UP

 button to adjust the color home position. Once the color has 

been  selected,  press  the 

ENTER

  button  to  setup  or  automatically  return  to  the  offset 

functions  without  any  change  press  the 

MENU

  button  again,  To  go  back  to  the  main 

functions without any change after 8 seconds. 

    Gobo offset 

Press the 

MENU

 button for at least 5 seconds into offset mode, use 

DOWN

 and 

UP

 button 

up to when the 

  is shown on the display. Pressing 

ENTER

 button and the display 

will blink. Use 

DOWN

 and 

UP

 button to adjust the gobo home position. Once the gobo has 

been  selected,  press  the 

ENTER

  button  to  setup  or  automatically  return  to  the  offset 

functions  without  any  change  press  the 

MENU

  button  again,  To  go  back  to  the  main 

functions without any change after 8 seconds. 

    Prism offset 

Press the 

MENU

 button for at least 5 seconds into offset mode, use 

DOWN

 and 

UP

 button 

up to when the 

  is shown on the display. Pressing 

ENTER

 button and the display 

will blink. Use 

DOWN

 and 

UP

 button to adjust the prism home position. Once the prism has 

been  selected,  press  the 

ENTER

  button  to  setup  or  automatically  return  to  the  offset 

functions  without  any  change  press  the 

MENU

  button  again,  To  go  back  to  the  main 

functions without any change after 8 seconds. 

Содержание MH-575S

Страница 1: ...RULER SPOT MH 575S User Guide Please read these instructions carefully before use 1...

Страница 2: ...wer before fuse lamp replacement or servicing l Replace fuse lamp only with the same type l Make sure there are no flammable materials close to the unit while operating as it is fire hazard l Use safe...

Страница 3: ...unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 2 Technical Specifi...

Страница 4: ...ng will otherwise be opened 3 Lamp WARNING Because of its high internal pressure there might be a risk that the Discharge lamp would explode during operation The lamp emits intense UV radiation which...

Страница 5: ...selected functions UP To go forward in the selected functions ENTER To confirm the selected functions DMX input output For DMX512 operation use 3 pin XLR plug cable to link the unit together 9 Power...

Страница 6: ...nge press the MENU button again Show 1 mode Fixture is placed on the floor Tilt movement angle 210 Show 2 mode Fixture is fixed under ceiling Tilt movement angle 90 Show 3 mode Fixture is placed on th...

Страница 7: ...ER button and the display will blink Use DOWN and UP button to select the normal or tilt inversion mode Once the mode has been selected press the ENTER 13 button to setup or automatically return to th...

Страница 8: ...been selected press the ENTER button to setup or automatically return to the offset functions without any change press the MENU button again To go back to the main functions without any change after 8...

Страница 9: ...ion You can select blackout mode in yes blackout or no blackout mode while the unit is turned on By linking the units in master slave connection the first unit will control the other units to give an...

Страница 10: ...a Y cable DMX512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input conne...

Страница 11: ...per address D No response to the sound 1 Make sure the unit is not receiving DMX signal 2 Check microphone to see if it is good by tapping the microphone E One of the channels is not working well 1 Th...

Страница 12: ...E that fix the bridge 4 Change a new belt F Please adjust the tension of the belt properly Note do not fix belt too tight as it is easy to rupture 5 Reverse the procedures from point 3 to 2 C C C B A...

Страница 13: ...re operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefu...

Страница 14: ...26 27 Innovation Quality Performance...

Отзывы: