10- 

 

 

11- 

   

DMX512 Address Setting

 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address.   

Once  the  address  has  been  selected,  press  the 

ENTER

  button  to  setup  or  automatically 

return to the main functions without any change after 8 seconds. To go back to the functions   

without any change press the

 MENU

 button again.

 

    Show Mode 

Press  the 

MENU

  button  up  to  when  the 

  is  showing  on  the  display.  Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 

(show 1) or 

  (show 2) or 

  (show 3) or 

  (show 4) mode. Once the 

mode has been selected, press the 

ENTER

 button to setup or automatically return to the 

main functions without any change after 8 seconds. To go back to the functions without any 

change press the

 MENU

 button again.   

    Show 1 mode - Fixture is placed on the floor. Tilt movement angle 210°. 

    Show 2 mode - Fixture is fixed under ceiling. Tilt movement angle 90°. 

    Show 3 mode - Fixture is placed on the speaker, The spot is always projecting   

to the audience’s direction; i.e in front of the stage. Pan movement angle ( left to 

right to left ): 160°.    Tilt movement angle:    90° ( 60° above horizon; 30° below 

horizon). 

    Show 4 mode - Fixture is fixed under ceiling. The spot is mainly projecting in 

front  of  the  stage.  Pan  movement  angle  (left  to  right  to  left)  :160°.    Tilt 

movement angle: 90° ( vertically, front 75°; back 15° ) .

 

   

Slave Mode

 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

(Master) 

or 

  (normal) or 

  (2 light show) mode. Once the mode has been selected, 

press the 

ENTER

 button to setup or automatically return to the main functions without any 

change after 8 seconds. To go back to the functions without any change press the

 MENU

 

button again. 

 

Содержание MH-575S

Страница 1: ...RULER SPOT MH 575S User Guide Please read these instructions carefully before use 1...

Страница 2: ...wer before fuse lamp replacement or servicing l Replace fuse lamp only with the same type l Make sure there are no flammable materials close to the unit while operating as it is fire hazard l Use safe...

Страница 3: ...unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 2 Technical Specifi...

Страница 4: ...ng will otherwise be opened 3 Lamp WARNING Because of its high internal pressure there might be a risk that the Discharge lamp would explode during operation The lamp emits intense UV radiation which...

Страница 5: ...selected functions UP To go forward in the selected functions ENTER To confirm the selected functions DMX input output For DMX512 operation use 3 pin XLR plug cable to link the unit together 9 Power...

Страница 6: ...nge press the MENU button again Show 1 mode Fixture is placed on the floor Tilt movement angle 210 Show 2 mode Fixture is fixed under ceiling Tilt movement angle 90 Show 3 mode Fixture is placed on th...

Страница 7: ...ER button and the display will blink Use DOWN and UP button to select the normal or tilt inversion mode Once the mode has been selected press the ENTER 13 button to setup or automatically return to th...

Страница 8: ...been selected press the ENTER button to setup or automatically return to the offset functions without any change press the MENU button again To go back to the main functions without any change after 8...

Страница 9: ...ion You can select blackout mode in yes blackout or no blackout mode while the unit is turned on By linking the units in master slave connection the first unit will control the other units to give an...

Страница 10: ...a Y cable DMX512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input conne...

Страница 11: ...per address D No response to the sound 1 Make sure the unit is not receiving DMX signal 2 Check microphone to see if it is good by tapping the microphone E One of the channels is not working well 1 Th...

Страница 12: ...E that fix the bridge 4 Change a new belt F Please adjust the tension of the belt properly Note do not fix belt too tight as it is easy to rupture 5 Reverse the procedures from point 3 to 2 C C C B A...

Страница 13: ...re operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefu...

Страница 14: ...26 27 Innovation Quality Performance...

Отзывы: