3.4   Universal   DMX   Controller       

When   using   a   universal   DMX   controller   to   control   the   chain   of   units,   you   have   to   set   a   DMX   

address.   Use   Dip   switches   1   to   9.   Dip   switch   10   is   used   to   choose   the   channel   mode.   Please   refer   

to   the   following   diagram   to   show   how   to   address   your   DMX   512   system   using   the   binary   code.   

DMX   512   Address   Chart:

       

 

Dip-­‐switches   

#   1   

#   2   

#   3   

#   4   

#   5   

#   6   

#   7   

#   8   

#   9   

#10   

Value   

1   

2   

4   

8   

16   

32   

64   

128    256   

N/A   

 

 

   

Examples:

   

Unit   1

dip   /   on:   #1   (=1)   

Unit   2

dip   /   on:   #2,   #3   (2+4=6)   

Unit   3

dip   /   on:   #1,   #2,   #4   (1+2+8=11)   

Unit   4

dip   /   on:   #5   (=16)   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание LED-SC25

Страница 1: ...LED SC25 User Manual Please read the instructions carefully before use ...

Страница 2: ...Specifications 3 3 How To Control The Unit 4 3 1 Control Panel 4 3 2 Master Slave Operation 5 3 3 Easy CA 8 Controller 5 3 4 Universal DMX Controller 6 4 DMX 512 Configuration 7 5 DMX 512 Connection 7 6 Troubleshooting 8 7 Cleaning and Maintenance 9 ...

Страница 3: ...s close to the unit while operating as it is a fire hazard Use safety cables when installing this unit Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where the temperature is higher than this Turn off the power and allow about 5 minutes for the unit to cool down before servicing In the event of a serious operating problem stop using the unit immediately Never try to repair the un...

Страница 4: ...nstalled by professionals It must be installed in a place where is out of the reach of people and no one can pass by or under it 2 Technical Specifications 5 DMX Channels Pan Tilt Gobo Colour Strobe Dimmer 8 gobos with dichroic colours plus open Smooth 0 100 dimming and various strobe effects 3 Operation Modes DMX Master Slave and Sound Activation Built in shows in master slave mode triggered by t...

Страница 5: ... to the next fixture 4 DMX IN DMX 512 link use 3 pin XLR cables to link the fixture to a DMX controller 5 Microphone Used to receive music for sound activation 6 Only for remote control Used to connect to the CA 8 to control the unit in Stand by Function and Mode 7 Only for wireless receiver Used to connect to the CA 9 RX to control the unit in Stand by Function and Mode ...

Страница 6: ...lave units DMX start address may have any value but NOT 001 example set the first 3 DIP switches to ON 3 3 Easy CA 8 Controller The easy CA 8 remote control is used only in master slave modes By connecting to the remote socket of the first unit you will find that the remote controller on the first unit will control all the other units in Stand by Function and Mode Stand by Blackout the unit Functi...

Страница 7: ...1 to 9 Dip switch 10 is used to choose the channel mode Please refer to the following diagram to show how to address your DMX 512 system using the binary code DMX 512 Address Chart Dip switches 1 2 3 4 5 6 7 8 9 10 Value 1 2 4 8 16 32 64 128 256 N A Examples Unit 1 dip on 1 1 Unit 2 dip on 2 3 2 4 6 Unit 3 dip on 1 2 4 1 2 8 11 Unit 4 dip on 5 16 ...

Страница 8: ...7 4 DMX 512 Configuration 5 Channels Mode 5 DMX 512 Connection ...

Страница 9: ... set to receive the data sent by the controller The address number is between 0 512 usually 0 1 are equal to 1 5 The end of the DMX 512 system should be terminated to reduce signal errors 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 6 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The fixtu...

Страница 10: ...l 2 Check the microphone by tapping it 7 Cleaning and Maintenance Cleaning must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates moist smoky or particularly dirty surroundings can cause a greater accumulation of dirt on the fixture Clean with lint free cloth using normal glass cleaning liquid or mild soapy water Clean ...

Страница 11: ...nce with the provision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 2009 EN55103 2 2009 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...

Страница 12: ...11 Innovation Quality Performance ...

Отзывы: