Connect the fixture together in a “daisy chain” by XLR plug cable from the output of the 

fixture  to  the  input  of  the  next  fixture.  The  cable  cannot  be  branched  or  split  to  a  “Y” 

cable. Inadequate or damaged cables, soldered joints or corroded connectors can easily 

distort the signal and shut down the system 

2.

 

The  DMX  output  and  input  connectors  are  pass-through  to  maintain  the  DMX  circuit 

when one of the units’ power is disconnected. 

3.

 

At  last  fixture,  the  DMX  cable  has  to  be  terminated  with  a  terminator  to  reduce  signal 

errors. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 

3-pin XLR-plug and plug it in the DMX-output of the last fixture. 

4.

 

Each lighting fixture needs to have an address set to receive the data sent by the controller. 

The address number is between 0-511 (usually 0 & 1 are equal to 1). 

5.

 

3 pin XLR connectors are more popular than 5 pins XLR. 

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), 

  Pin4/5: not used 

8. Troubleshooting   

Following  are  a  few  common  problems  that  may  occur  during  operation.  Here  are  some 

suggestions for easy troubleshooting: 

A. The fixture does not work, no light 

1.

 

Check the connection of power and main fuse. 

2.

 

Measure the mains voltage on the main connector. 

 

B. Not responding to DMX controller 

1.

 

DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.

 

If the DMX LED is on and no response to the channel, check the address settings and DMX 

polarity. 

3.

 

If you have intermittent DMX signal problems, check the pins on connectors or on PCB of 

Содержание LED-LP400

Страница 1: ...LED LP400 User Manual Please read it carefully before using...

Страница 2: ...ons 3 3 Installation 3 4 How To Set The Fixture 4 4 1 Control Panel 4 4 2 Main Function 5 5 How To Control The Unit 8 5 1 Master Slave Function 9 5 2 DMX Controller 9 6 DMX512 Configuration 10 7 DMX51...

Страница 3: ...re there are not flammable materials close to the unit while operating as it is fire hazard y Use safety cable when fixes this unit y Maximum ambient temperature is TA 40 and don t operate it where th...

Страница 4: ...mension 406 x 356 x 114mm y Weight 6 2KG 3 Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while...

Страница 5: ...forward in the selected functions ENTER To confirm the selected functions 4 Battery Switch Used to connect or disconnect the battery power supply 5 Dimmer Adjust Knob Used to adjust lightness for the...

Страница 6: ...ect the function by the ENTER button and the display will blink Use the DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup or it will automa...

Страница 7: ...button and the display will blink Use the DOWN and UP button to change the DMX 512 address Once the address has been selected press the ENTER button to setup or automatically exit menu mode without an...

Страница 8: ...NTER button to setup or automatically exit menu mode without any change after 8 seconds To go back to the functions without any change press the MENU button DMX State Press the MENU button up to when...

Страница 9: ...ay Pressing ENTER button and the display will show the number of working hours of the unit To go back to the functions press the MENU button Software version Press the MENU button up to when the is bl...

Страница 10: ...at the units can receive DMX signal Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX512 address...

Страница 11: ...10A 6 DMX512 Configuration 2 3 Channels Mode 7 DMX512 Connections The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels...

Страница 12: ...ave an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 5 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND...

Страница 13: ...r motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 9 Fixture Cleaning The cleaning of internal must be carried out periodi...

Страница 14: ......

Страница 15: ...the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1...

Страница 16: ...Innovation Quality Performance...

Отзывы: