6.
The end of the DMX 512 system should be terminated to reduce signal errors.
7.
3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+),
Pin 4/Pin 5: Not used.
4.2 Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to
512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select
DMX Functions
, press the ENTER button to
confirm, use the UP/DOWN button to select
DMX Address
, press the ENTER button to confirm,
the present address will blink on the display, use the UP/DOWN button to adjust the address from
001 to 512, and press the ENTER button to store. Press the MENU button back to the last menu or
let the unit idle 7 seconds to exit menu mode.
Please refer to the following diagram to set the DMX address for the first 4 units:
Channel mode
Unit 1
Address
Unit 2
Address
Unit 3
Address
Unit 4
Address
11 channels
1
12
23
34
15 channels
1
16
31
46
14 channels
1
15
29
43
4.3 DMX512 Configuration
11 Channels Mode:
CHANNEL
VALUE
FUNCTION
1
000-255
PAN
0%
100%
2
000-255
TILT
0%
100%
3
PAN/TILT SPEED
15H