background image

 

16A 

Technical Specification   

 

Voltage:

AC100-240V, 50/60Hz 

Power consumption:5W

 

Dimension/ Weight:

 

174x148x144mm, 1.9Kg   
6.9"x5.8"x5.7"in, 4.2lbs   

 

 

Содержание CA-AN04T

Страница 1: ...CA AN04T...

Страница 2: ...ront Rear View 5 4 Operation Guide 6 4 1 Startup View 6 4 2 Main menu 7 4 2 1 Rename Device 7 4 2 2 Set IP Address 8 4 2 3 Set Netmask 8 4 2 4 Set DMX port 8 4 2 5 Set ID NO 12 4 2 6 Set LCD Backlight...

Страница 3: ...ect the device to any dimmer pack The housing must be replaced if they are visibly damaged Unit surface temperature may reach up to 85 Don t touch the housing bare hand during its operation Turn off t...

Страница 4: ...ions hanging upside down from a ceiling or set on a flat level surface To avoid internal damage to the unit never mount the unit on its side as illustrated above Be sure this fixture is kept at least...

Страница 5: ...ut can be set as single zero HTP LTP RDM mode Each DMX input can be set as normal backup mode Can be acted as DMX RDM splitter IP address can be set manually OLED display indicates each DMX port statu...

Страница 6: ...WN To go to move down in the menu ENTER To perform the desired functions 2 OLED Display Display the present status and the available option 3 LED indicator To show the power signal status of the unit...

Страница 7: ...to the DMX port Ethernet IN Ethernet Thru 1 2 3 4 refers to the DMX port 1 2 3 4 In the first line x means the port status is activity inactive means the current port status is disabled In the second...

Страница 8: ...n menu by press MENU then pressing the UP and DOWN to choose the Rename Device option and then press the ENTER to confirm your selection Now you can rename the device by pressing UP and DOWN now Confi...

Страница 9: ...onfirm you change by press the ENTER Please note Each of the IP address should be unique 4 2 3 Set Netmask Enter into the main menu by press MENU then pressing the UP and DOWN to choose the Netmask op...

Страница 10: ...t as normal or backup 3 Framerte fs 4 NET 5 Principal 6 Secondary 7 Resend 8 Display Mode Dec Normal mode means it will send the data received from DMX IN port to the universal of network regardless i...

Страница 11: ...of principle and secondly The unit will compare the two universal and resend the later one to the network Please note that in the LTP mode you should ensure the Resend option is not at the status of D...

Страница 12: ...ort Remote Device Manager 3 1 3 DMX port disabled Any of the port 1 4 can be set as Disabled status Upon the port has been set as Disabled status the DMX port will be disabled it cannot send or receiv...

Страница 13: ...d DOWN to choose the Set LCD Backlight option and then press the ENTER to confirm your selection You can choose its status as ON OFF ON means the LCD backlight will turn on all the time OFF means the...

Страница 14: ...with one DMX input to 3 DMX output Please note that the LED indicator of the DMX Output port will light up in green 3 ArtNet Clone Direct through mode the preset is used to replicate a standard ArtNe...

Страница 15: ...e the signal from the network individually 5 Factory Setting All of the setting including the device name device ID as well as device IP will be restored to the original status 4 2 8 Version You can c...

Страница 16: ...15A 5 Application Diagram Please Note that the unit cannot be circular connected or it will cause cyber storm to affect the performance of system...

Страница 17: ...16A Technical Specification Voltage AC100 240V 50 60Hz Power consumption 5W Dimension Weight 174x148x144mm 1 9Kg 6 9 x5 8 x5 7 in 4 2lbs...

Страница 18: ...17A It can be installed in truss of different sizes 40MM 50MM 60MM...

Страница 19: ...18A...

Страница 20: ...h the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 A1 2012 EN55103 2 2009 EN61000 3 2 2014 EN61000 3 3 2013 Harmonized Standard EN 60598 1 2015 EN 60598 2 17...

Отзывы: