7. Error Information
1. Led Temp. Error
Check if the temperature detecting board is normal.
Check if the components of the temperature detecting board are damaged.
Check if the lead of the temperature detecting board is installed in place or disconnected.
2. LED Too Hot Off
When the fixture temperature reaches 65
℃
, it will automatically turn off to protect the fixture.
3. LED Timeout Use
8. Troubleshooting
Following are a few common problems that may occur during operation. Here are some
suggestions for easy troubleshooting:
A. The unit does not work and no light
1. Check the connect power.
2. Measure the mains voltage on the main connector.
3. Check the power on LED to see if it can be light up or not.
B. Not responding to DMX controller
1. Check DMX connectors, cables to see if they are linked properly.
2. Check the address settings and DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the
unit or the previous one.
4. Try to use another DMX controller.
5. Check to see if the DMX cables run near or run alongside to high voltage cables that may cause
damage or interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.