Acksys SWA A10 Скачать руководство пользователя страница 3

Documentation ref DTUS075 rev A0 06/18/20 

-3- 

 

NOMENCLATURE 

 

SWA 

A10 

33 

42 

X0 

 

1 – Enclosure  

         SWA Aluminium polyester powder coated 

         SWS Stainless steel AISI 316 (CF8M) electropolish 

4 – Cable entries 

         42     n° 4 3/4” npt-f (two used for antenna connection) 

         44     n° 4 M25x1.5 (two used for antenna connection) 

2 –  Device code 

         A10   802.11n, MIMO 2x2 

         A11   802.11ac, MIMO 2x2 

         A12   802.11n, MIMO 2x2 plus 802.11ac (1 stream) 

5 – Colour 

         0     black polyester powder coating (SWA series only) 

         E     electropolished (SWS housings only) 

3 – Antenna connection 

         30     n° 3 RXN antenna coupler (N Female)  

         33     n° 2 RXN antenna coupler (N Female) 

6 – Approvals 

         X0     Atex/IECEx Gas and Dust certified, Zone 1, 2, 21 & 22   

         M0    Atex/IECEx Gas, Dust and mining certified, Zone 1, 2, 21 & 22 

         N0    QPS CL1 DIV1 and North American Zones listed 

PRODUCT’S STORAGE 

Keep the boxes away from atmospheric agents in an environment with 

temperature between 0°C and 40°C. 

 

INSTALLATION 

Attach the enclosure to a fix surface using four M6 bolts 

The unit can be installed in all position. 

 

ELECTRICAL WIRING 

Remove screw cover, remove protection plugs from cable entries and 

substitute them with cable glands or conduits or plugs suitable for type of 

protection required. 

Connect terminal strip according to the wiring diagram present into the Annex 

to Installation & Operation Manual.  

Reassemble screw cover and lock it by means of the screw or anti rotation 

kit. 

WARNING: Before closing the enclosure check that thread joint were free of 

foreign matters and deformations check seal is properly fitted in slot.  

The cover must be screwed and securely locked to the body. 

 

MAINTENANCE 

The verification and maintenance of the electrical equipment must be 

performed according to IEC/EN 60079-17. 

The cover must be securely locked to the body.  

After every opening must to check before closing 

that he thread joint is free of foreign matters and 

deformations and if necessary lubricate the thread 

joint in order to avoid cover blocking with grease 

like Nyogel 760G, Uniflor 8512R, Uniflor 8911 

compatible with silicon gasket or equivalent 

according to enclosure temperature range. 

In order to guarantee the protection degree IP66-

68 it’s necessary that the gasket is maintained in 

good conditions and must be verified after every 

opening that the same does not show breakage or 

cuttings. In case of damage replace with ACKSYS spare part. 

The maintenance related the components used for wiring must be performed 

according to manufacturer instruction. 

 

DISPOSAL / RECYCLING 

Disposal and recycling of the product according to national regulation for 

waste disposal and recycling. 

WARNING: Do not dispose the product and the components in the 

environment.  

 

 

 

 

 

 

 

 

Содержание SWA A10

Страница 1: ...read the full manual WaveOS user guide You will need a PC equipped with Ethernet access to install the WaveManager software a web browser IE compatible an android smartphone if you want to install the...

Страница 2: ...fety characteristic of the device after maintenance 9 If the equipment is likely to come in to contact with aggressive substances it is responsibility of the user to take suitable precautions that pre...

Страница 3: ...ring diagram present into the Annex to Installation Operation Manual Reassemble screw cover and lock it by means of the screw or anti rotation kit WARNING Before closing the enclosure check that threa...

Страница 4: ...A11 A12 POWER SUPPLY Screw terminals Supply voltage 18 60 VDC RJ45 connector PPoE 24 VDC or PoE 48 VDC Max Power Consumption 8W for A10 14W for A11 and A12 PPoE Passive Power over Ethernet operating...

Страница 5: ...edance and with operating frequency in according to technical data listed into the above paragraph RF information The device must be set according to limitation listed at paragraph MAXIMUM PERMITTED R...

Страница 6: ...n or ac mode 5GHz band auto channel WEB interface for device configuration IP address 192 168 1 253 User name root Password no password set as factory setting Step 1 Verify that the IP address factory...

Страница 7: ...try selector is located in the global parameters near the bottom of the page You can select radio interface to set up its WiFi parameters you can also change IP configuration and services In function...

Страница 8: ...t come up Make sure that the Wireless parameters of the Client case sensitive SSID 802 11 mode radio channel and security match those of the AP Check the radio conditions distance between devices plac...

Страница 9: ...ANTENNA 1 AND 2 Radio modes Support for IEEE 801 11a h 802 11b 802 11g 802 11n and 802 11ac Frequency band for 802 11a n 5 GHz 5 170 to 5 835 GHz Frequency band for 802 11b g n 2 4 GHz 2 402 to 2 494...

Страница 10: ...n 5 GHz 5 170 to 5 835 GHz Frequency band for 802 11b g n 2 4 GHz 2 402 to 2 494 GHz Tx output power Radio card output per chain antenna excluded 802 11b 2 4GHz band 20 dBm 1 Mbps 20 dBm 11 Mbps 802 1...

Страница 11: ...3 5 35 4 Group IIC 2 33 0 Group III 6 37 7 The above threshold level refer to installation in classified area Ex according to IEC EN 60079 0 standard The use of device differs from one region and or...

Страница 12: ...Mb SWS series only IP66 68 Atex certificate number EXA 14 ATEX 0042 IECEx identification Ex db IIC T5 T4 Gb Ex tb IIIC T110 C T140 C Db Ex db I Mb SWS series only IP66 68 IECEx certificate number IEC...

Отзывы: