Refrigerant piping

Connection

 

5. While firmly gripping the nut, use a torque

wrench to tighten the flare nut according

to the torque values in above table.

NOTE: 

Use both a spanner and a torque wrench 

when connecting or disconnecting pipes to/from 

the unit.

 

 CAUTION

Ensure to wrap insulation around the piping.

Direct contact with the bare piping may

result in burns or frostbite.

Make sure the pipe is properly connected.

Over tightening may damage the bell mouth

and under tightening may lead to leakage.

NOTE ON MINIMUM BEND RADIUS

Carefully bend the tubing in the middle 

according to the diagram below. 

DO NOT 

bend 

the tubing more than 90° or more than 3 times.  

 

Bend the pipe with thumb

min-radius 10cm (3.9”)

6.

 

After connecting the copper pipes to the indoor

unit, wrap the power cable, signal cable and the

piping together with binding tape.

NOTE: DO NOT 

intertwine signal cable with 

other wires. While bundling these items 

together, do not intertwine or cross the signal 

cable with any other wiring. 

 

7. Thread this pipeline through the wall and

connect it to the outdoor unit.

8. Insulate all the piping, including the valves of

the outdoor unit.

9. Open the stop valves of the outdoor unit to

start the flow of the refrigerant between the

indoor and outdoor unit.

 CAUTION

Check to make sure there is no refrigerant leak 

after completing the installation work. If there is 

a refrigerant leak, ventilate the area immediately 

and evacuate the system (refer to the Air 

Evacuation section of this manual).    

Содержание ACiQ-12FM-HH-MB

Страница 1: ...ation Manual ACiQ 12FM HH MB ACiQ Floor Mounted Type Air Conditioner IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference ...

Страница 2: ... and Features 07 Owner s Manual Table of Contents Safety Precautions 04 Care and Maintenance 11 Troubleshooting 13 1 Indoor unit display 07 2 Operating temperature 09 3 4 Adjusting Air Flow Direction 10 Other features 09 ...

Страница 3: ...stall drain joint 25 Wiring 31 1 Outdoor Uint Wiring 32 3 Power Specifications 34 3 Anchor outdoor unit 25 Refrigerant Piping Connection 27 A Note on Pipe Length 27 B Connection Instructions Refrigerant Piping 28 1 Cut pipe 28 2 Remove burrs 28 3 Flare pipe ends 29 4 Connect pipes 29 Air Evacuation 35 1 Evacuation Instructions 35 2 Note on Adding Refrigerant 36 Test Run 37 Installation Summary 17 ...

Страница 4: ...ng smell immediately turn off the unit and disconnect the power Call your dealer for instructions to avoid electric shock fire or injury Do not insert fingers rods or other objects into the air inlet or outlet This may cause injury since the fan may be rotating at high speeds Do not use flammable sprays such as hair spray lacquer or paint near the unit This may cause fire or combustion Do not oper...

Страница 5: ...ension cord to power the unit Do not share the electrical outlet with other appliances Improper or insufficient power supply can cause fire or electrical shock If connecting power to fixed wiring an all pole disconnection device which has at least 3mm clearances in all poles and have a leakage current that may exceed 10mA the residual current device RCD having a rated residual operating current no...

Страница 6: ... install the appliance to its support please read the information for details in indoor unit installation and outdoor unit installation sections For units that have an auxiliary electric heater do not install the unit within 1 meter 3 feet of any combustible materials Do not install the unit in a location that may be exposed to combustible gas leaks If combustible gas accumulates around the unit i...

Страница 7: ...mode the Operation light flashes The system will then turn to AUTO after it has cooled with a high wind speed for 30 minutes The remote control will be disabled during this operation OFF mode The unit turns off and the remote control is re enabled Infrared receiver Timer indicator PRE DEF pre heating defrost indicator Operation indicator Manual button Infrared receiver Operation indicator Manual b...

Страница 8: ...perature 17 C 32 C 62 F 90 F 0 C 30 C 32 F 86 F 10 C 32 C 50 F 90 F Outdoor Temperature 18 C 43 C 64 F 109 F 7 C 24 C 19 F 75 F 11 C 43 C 52 F 109 F 7 C 43 C 19 F 109 F For models with low temp cooling systems 18 C 43 C 64 F 109 F 18 C 52 C 64 F 126 F For special tropical models 18 C 52 C 64 F 126 F For special tropical models COOL mode HEAT mode DRY mode COOL mode HEAT mode DRY mode Room Temperat...

Страница 9: ...ill restart using the same settings Louver Angle Memory Function some models Some models are designed with a louver angle memory function When the unit restarts after a power failure the angle of the horizontal louvers will automatically return to the previous position The angle of the horizontal louver should not be set too small as condensation may form and drip into the machine To reset the lou...

Страница 10: ... air outlets Manual Swing Press Air Direction to fix the louver at a desired angle The louver swings upward or downward at a different angle with each press of the button When cooling Adjust the louver downwards horizontally When heating Adjust the louver vertically Adjust the Air Flow Direction Left and Right Hold the knob and move the louver You will find a knob on the left side and the right si...

Страница 11: ...your health Make sure to clean the filter once every two weeks WARNING DO NOT REMOVE OR CLEAN THE FILTER BY YOURSELF Removing and cleaning the filter can be dangerous Removal and maintenance must be performed by a certified technician Care and Maintenance 1 Open the front panel 2 Remove the air filter Press the claws on the right and left sides of the air filter down slightly then pull upward 5 Ri...

Страница 12: ...eaks Replace batteries Make sure nothing is blocking all air inlets and outlets CAUTION Before changing the filter or cleaning turn off the unit and disconnect its power supply When removing filter do not touch metal parts in the unit The sharp metal edges can cut you Do not use water to clean the inside of the indoor unit This can destroy insulation and cause electrical shock Do not expose filter...

Страница 13: ... due to expansion and contraction of the unit s plastic parts Both the indoor unit and outdoor unit make noises Low hissing sound during operation This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units Low hissing sound when the system starts has just stopped running or is defrosting This noise is normal and is caused by the refrigerant gas stopping or changi...

Страница 14: ... detailed description of the unit malfunction as well as your model number Troubleshooting When troubles occur please check the following points before contacting a repair company Problem Possible Causes Solution Poor Cooling Performance Temperature setting may be higher than ambient room temperature Lower the temperature setting The heat exchanger on the indoor or outdoor unit is dirty Clean the ...

Страница 15: ...emely low Use auxiliary heating device Cold air is entering through doors and windows Make sure that all doors and windows are closed during use Low refrigerant due to leak or long term use Check for leaks re seal if necessary and top off refrigerant Indicator lamps continue flashing The unit may stop operation or continue to run safely If the indicator lamps continue to flash or error codes appea...

Страница 16: ... between indoor unit and outdoor unit after installation some models S1 S2 P Q E Copper nut 2 Accessories Soundproof insulation sheath some models 2 1 Red short connected wire some models The air conditioning system comes with the following accessories Use all of the installation parts and accessories to install the air conditioner Improper installation may result in water leakage electrical shock...

Страница 17: ...tall the outdoor unit L L1 N L2 1 2 3 4 5 MC MC 6 7 Install the indoor unit Evacuate the refrigeration system Connect the wires Connect the refrigerant pipes Perform a test run Page 17 Installation Summary Installation Summary ...

Страница 18: ...he actual shape shall prevail NOTE The installation must be performed in accordance with the requirement of local and national standards The installation may be slightly different in different areas Unit Parts Display panel Drain pipe Connecting pipe Air inlet Air outlet Air flow louver at air outlet Air inlet with air filter in it 1 1 2 3 4 5 6 6 7 1 2 3 4 5 6 7 ...

Страница 19: ...gh room exists for installation and maintenance Enough room exists for the connecting the pipe and drainpipe The ceiling is horizontal and its structure can sustain the weight of the indoor unit The air inlet and outlet are not blocked The airflow can fill the entire room There is no direct radiation from heaters DO NOT install unit in the following locations Areas with oil drilling or fracking Co...

Страница 20: ... the mounting plate with a tapping screw onto the wall Mounting plate Tapping screw Washer 6mm Hang the indoor unit on the mounting plate The bottom of body can touch the floor or remain suspended but the body must be installed vertically Mounting plate 173mm 94mm 285mm ...

Страница 21: ...ion purposes only The air conditioner you have purchased may be slightly different in design though similar in shape Slide the two stoppers on the left and right sides inward until they click 3 Remove the face plate Remove the four screws Open the bottom of the face plate at a 30 degree angle Lift the top of the face plate Remove the string Allow the front panel to fall forward and remove it ...

Страница 22: ...roper water drainage 3 Place the protective wall cuff in the hole This protects the edges of the hole and will help seal it when you finish the installation process CAUTION When drilling the wall hole make sure to avoid wires plumbing and other sensitive Wall Indoor Outdoor 12mm 0 5 inch Step 4 Network address set some models Only unit of 18000Btu h has the function that Network address set Every ...

Страница 23: ...unction In HEAT mode the outdoor unit will discharge water Ensure that the drain hose is placed in an appropriate area to avoid water damage and slippage DO NOT pull the drainpipe forcefully This could disconnect it NOTE ON PURCHASING PIPES Installation requires a polyethylene tube exterior diameter 3 7 3 9cm interior diameter 3 2cm which can be obtained at your localhardware store or dealer 1 2 D...

Страница 24: ...air outlet fan is at a 90 angle to the direction of the wind If needed build a barrier in front of the unit to protect it from extremely heavy winds See Figures below Strong wind Strong wind Strong wind If the unit is frequently exposed to heavy rain or snow Build a shelter above the unit to protect it from the rain or snow Be careful not to obstruct air flow around the unit If the unit is frequen...

Страница 25: ...see Fig B do the following 1 Insert the drain joint into the hole in the base pan of the unit The drain joint will click in place 2 Connect a drain hose extension not included to the drain joint to redirect water from the unit during heating mode Seal Drain joint A B Base pan hole of outdoor unit Seal IN COLD CLIMATES In cold climates make sure that the drain hose is as vertical as possible to ens...

Страница 26: ...16 14 673 26 5 403 15 87 952x1333x410 37 5x52 5x16 14 634 24 96 404 15 9 890x673x342 35x26 5x13 46 663 26 1 354 13 94 952x1333x415 37 5x52 5x16 34 634 24 96 404 15 9 845x702x363 33 27x27 6x14 3 540 21 26 350 13 8 938x1369x392 36 93x53 9x15 43 634 24 96 404 15 9 900x1170x350 35 4x46x13 8 590 23 2 378 14 88 800x554x333 31 5x21 8x13 1 514 20 24 340 13 39 780x540x250 30 7x21 25x9 85 549 21 6 276 10 85...

Страница 27: ...ts meets the requirements shown in the following table The Maximum Length And Drop Height Based on Models Unit m ft Type of model Capacity Btu h Length of piping Maximum drop height North America Australia and the eu frequency conversion Split Type 15K 25 82 10 32 8 15K 24K 30 98 4 20 65 6 24K 36K 50 164 25 82 36K 60K 65 213 30 98 4 Other Split Type 12K 15 49 8 26 18K 24K 25 82 15 49 30K 36K 30 98...

Страница 28: ...Warped 90 DO NOT DEFORM PIPE WHILE CUTTING Be extra careful not to damage dent or deform the pipe while cutting This will drastically reduce the heating efficiency of the unit Step 2 Remove burrs Burrs can affect the air tight seal of refrigerant piping connection They must be completely removed 1 Hold the pipe at a downward angle to prevent burrs from falling into the pipe Step 1 Cut pipes When p...

Страница 29: ...re the pipe in accordance with the dimensions PIPING EXTENSION BEYOND FLARE FORM 8 Remove the flaring tool and flare form then inspect the end of the pipe for cracks and even flaring Step 4 Connect pipes Connect the copper pipes to the indoor unit first then connect it to the outdoor unit You should first connect the low pressure pipe then the high pressure pipe 1 When connecting the flare nuts ap...

Страница 30: ... or more than 3 times Bend the pipe with thumb min radius 10cm 3 9 6 After connecting the copper pipes to the indoor unit wrap the power cable signal cable and the piping together with binding tape NOTE DO NOT intertwine signal cable with other wires While bundling these items together do not intertwine or cross the signal cable with any other wiring 7 Thread this pipeline through the wall and con...

Страница 31: ... same power circuit 16 Connect the outdoor wires before connecting the indoor wires 7 Only connect the unit to an individual branch circuit outlet Do not connect another appliance to that outlet 8 Make sure to properly ground the air conditioner 9 Every wire must be firmly connected Loose wiring can cause the terminal to overheat resulting in product malfunction and possible fire Do not let wires ...

Страница 32: ... Indoor Outdoor connective wires Outdoor unit power wires C NOTE The cographs are for explanation purpose only Your machine may be slightly different The actual shape shall prevail Indoor unit Outdoor unit Air switch Air switch purchased seperately Only for the North American purchased seperately purchased seperately Outdoor unit power wires Indoor Outdoor connective wires D NOTE In North America ...

Страница 33: ...cable for connection a Using wire strippers strip the rubber jacket from both ends of the signal cable to reveal about 15cm 5 9 of the wire b Strip the insulation from the ends of the wires c Using a wire crimper crimp the u lugs to the ends of the wires 2 Rotate the sensor device s installation bearer to the other side Then remove the cover of the electrical box Also remove the electrical box als...

Страница 34: ...IRCUIT BREAKER FUSE A INDOOR UNIT POWER WIRING mm OUTDOOR UNIT POWER WIRING GROUND WIRING STRONG ELECTRIC SIGNAL WEAK ELECTRIC SIGNAL INDOOR OUDOOR CONNECTING WIRING mm 16K 1 Phase 220 240V 50Hz 60Hz 20 16 3x1 5 4x1 0 1 5 16K 18K 1 Phase 220 240V 50Hz 60Hz 20 16 3x1 0 3x2 5 3x0 2 2 5 Page 34 Wiring ...

Страница 35: ...inutes or until the Compound Meter reads 76cmHG 105 Pa 2 3 4 5 6 Close the Low Pressure side of the manifold gauge and turn off the vacuum pump 7 Wait for 5 minutes then check that there has been no change in system pressure 8 If there is a change in system pressure refer to Gas Leak Check section for information on how to check for leaks If there is no change in system pressure unscrew the cap fr...

Страница 36: ...tandard pipe length x60g 0 64oZ m ft Total pipe length standard pipe length x65g 0 69oZ m ft R410A orifice tube in the indoor unit Total pipe length standard pipe length x30g 0 32oZ m ft Total pipe length standard pipe length x65g 0 69oZ m ft Total pipe length standard pipe length x115g 1 23oZ m ft R410A orifice tube in the outdoor unit Total pipe length standard pipe length x15g 0 16oZ m ft Total...

Страница 37: ...rectly d Ensure the indicators on the remote control and the display panel on the indoor unit work properly e Ensure the manual buttons on the indoor unit works properly f Check to see that the drainage system is unimpeded and draining smoothly g Ensure there is no vibration or abnormal noise during operation 5 For the Outdoor Unit a Check to see if the refrigeration system is leaking b Make sure ...

Страница 38: ...ign and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version ...

Отзывы: