background image

Automation Components, Inc.

2305 Pleasant View Road  |  Middleton, WI 53562

Phone:

 1-888-967-5224  |  

Website:

 workaci.com

Page 1

Version: 5.0

I0000345

2.75"

(69.85 mm)

1.12"

(28.55 mm)

4.50"

(114.30 mm)

ROOM, VERSION 1

[R]

FRONT

BOTTOM

RIGHT

FIGURE 1: 

ROOM DIMENSIONS

ROOM SERIES

Installation & Operation Instructions

PCB: SOLO

Phone:

 1-888-967-5224

Website:

 workaci.com

PRECAUTIONS

• DO NOT RUN THE WIRING IN ANY CONDUIT 

WITH LINE VOLTAGE (24/120/230 VAC).

• THE OPTIONAL ACI/LCD MUST BE POWERED 

WITH EITHER A 24 VAC OR 9-35 VDC POWER 
SOURCE.

MOUNTING INSTRUCTIONS

Separate the cover from the base. Attach the base 
directly to the wall or to a standard 2” x 4” junction box 
using the (2) #6-32 x 1” screws provided. 

Take care when mounting. Check local code for 
mounting height requirements. Typical mounting 
heights are 48-60” (1.2-1.5 m) off the ground and at least 
1.5’ (0.5 m) from the adjacent wall. The sensor should be 
mounted in an area where air circulation is well mixed 
and not blocked by obstructions. 

*Reference FIGURE 2 (next page)

For optimal temperature measurement, follow 
these tips:  

Do not install on external walls.

Avoid air registers, diffusers, vents, and windows.

Avoid confined areas such as shelves, closed 

cabinets, closets, and behind curtains.

Eliminate and seal all wall and conduit penetrations. Air 

migration from wall cavities may alter temperature 
readings.

A thermally-insulated backing should be used when 

fitting to solid walls (concrete, steel, etc.). ACI part: 
A/ROOM-FOAM-PAD

Do not install near heat sources, eg: lamps, 

radiators, direct sunlight, copiers, chimney walls, 
walls concealing hot-water pipes.

Refer to the wiring instructions (p. 2) to make 
necessary connections. After wiring, attach the cover 
to the base by snapping the top of the cover on first 
and then the bottom. 

MOUNTING

 (Continued)

Tighten the cover down, using the (2) 1/16” Allen 
screws located in the bottom of the housing. A 
1/16” Hex driver is needed to secure the cover to 
the base. 

Mounting Instructions for optional ACI/LCD

The ACI/LCD is shipped as a two-piece unit.  The 
LCD Module must be unplugged from the 10 pin 
connector before the base of the sensor may be 
mounted to either the drywall or over a standard 
2” x 4” Junction Box using the mounting 
hardware provided.  The LCD Module should 
then be gently inserted into the 10 pin 
connector. The cover may now be placed onto 
the unit and tightened down using the (2) Allen 
screws at the bottom of the housing.

Содержание ROOM Series

Страница 1: ...gisters diffusers vents and windows Avoid confined areas such as shelves closed cabinets closets and behind curtains Eliminate and seal all wall and conduit penetrations Air migration from wall cavities may alter temperature readings A thermally insulated backing should be used when fitting to solid walls concrete steel etc ACI part A ROOM FOAM PAD Do not install near heat sources eg lamps radiato...

Страница 2: ...low and high voltage wires 24 120 230 VAC All ACI thermistors are non position sensitive All thermistor type room units are supplied with a two pole terminal block The number of wires needed depends on the application All wiring must comply with all local and National Electric Codes Note When using a shielded cable be sure to connect only 1 end of the shield to ground at the controller Connecting ...

Страница 3: ...MPERATURE DISPLAY ADJUSTMENTS The Temperature Display may be adjusted by adjusting the ZERO or OFFSET Potentiometer P2 as shown on the above diagram Adjust P2 until the LCD Display reading matches your controller if necessary SETPOINT CONTROL Adjust slider at bottom of housing for set point control Slide to right to increase set point temperature Slide to left to decrease temperature control One 1...

Страница 4: ...ty Verify sensor or wires are not shorted together Verify controller is setup for correct sensor curve Disconnectwiresfromsensorterminalblock tightenterminalblock screwsdown andtakearesistance ohm readingwithamultimeter Compare the resistance reading to theTemperatureVs Resistance Curves online http www workaci com content thermistor curves 0 Verify proper mounting location to confirm no external ...