background image

Automation Components, Inc.

2305 Pleasant View Road  |  Middleton, WI 53562

Phone:

 1-888-967-5224  |  

Website:

 workaci.com

Page 1

Version: 3.0

I0000230

GENERAL INFORMATION

The GP Series pressure sensor is a 4-20mA current 
output device that is designed to provide excellent 
accuracy and reliability in commercial, industrial, and 
process control applications where performance is 
critical.  The GP Series is available in two pressure 
sensing types: Gage (PSIG) and Sealed Gage (PSIS).  
Gage sensors (PSIG) measure pressure relative to 
ambient pressure through a port that is open to the 
atmosphere, and are used in lower pressure 
applications where measurement in a vacuum is not 
required.  Sealed sensors (PSIS) measure pressure 
relative to a port that is connected to a sealed perfect 
vacuum chamber.  Sealed pressure transducers are 
calibrated to have 4 mA at +14.5 PSIA.

OPTIONAL ACCESSORIES

Pressure Snubber

ACI recommends the use of the A/0.25” Snubber 
(Water or Air/Gas) with all GP series sensors.  The use 
of a pressure snubber is a cost-effective solution that 
can extend the life of your sensor by smoothing out 
pressure spikes, surges and pulsations, and prevent 
debris from collecting in the sensor diaphragm 
opening. The A/0.25” Snubbers are made of 316 Stainless Steel and should be used with compatible 
materials.

Syphons

The A/Syphon must be used to protect the sensor from extreme operating temperatures when the 
operating temperature of the steam being monitored is higher than the maximum operating temperature 
of the GP pressure sensor.  There are three bend configurations available (90˚, 180˚, and 270˚) to allow the 
mounting of the sensor vertically away from the main pipe.  

NEMA 4 Enclosure

ACI recommends the use of a NEMA 4 enclosure to protect the gage pressure sensor in applications where 
debris and moisture could contact the sensor or electrical connections.  The A/GP-(xx)-NEMA 4 GP Series 
pressure sensor is mounted in a NEMA 4 Rated, steel enclosure with one ½” conduit knockout.  A ¼” male 
NPT Stainless Steel fitting is provided for installation to your pipe, tank, or reservoir.

FIGURE 1: 

PRODUCT DIMENSIONS

GP SERIES GAGE PRESSURE

TRANSDUCER

Installation & Operation Instructions

Phone:

 1-888-967-5224

Website:

 workaci.com

                      

1/4” - 18 NPT 

Male Thread

2.77” (70.36mm)

Ø0.87” 

(22.07m

m)

0.71” 

(18.03mm)

1.06” 

(27.00mm)

0.78” (19.81mm)

0.88”

(22.35mm)

Содержание GP Series

Страница 1: ...e life of your sensor by smoothing out pressure spikes surges and pulsations and prevent debris from collecting in the sensor diaphragm opening The A 0 25 Snubbers are made of 316 Stainless Steel and should be used with compatible materials Syphons The A Syphon must be used to protect the sensor from extreme operating temperatures when the operating temperature of the steam being monitored is high...

Страница 2: ...t use excessive amounts of sealant or you might block the pressure going into the transducer Install the device using a wrench on the hex flats provided Do not use a strap wrench on the body When installing the GP sensor the torque limit is 150 in lbs 16 95 Nm Do Not over tighten Overtightening metal fittings may cause a slight zero shift The use of plastic fittings typically results in no noticea...

Страница 3: ...gnal is Inaccurate SOLUTION S ConfirmtheDCsupplyvoltageis 4 20mAOutput 250OhmLoad 13to30VDC 500OhmLoad 18 to 30VDC DisconnectthesensorfromthelinetoensureNoderisorsedimentis blockingtheinletportofthetransducer Determinethattheproperoutputisbeingtransmittedbasedonthe predetermined span Measure the output of the transmitter with a handheld multimeter and compare the measured output to calculate outpu...

Страница 4: ...teel 1 4 18 NPT 800 Ω 24 VDC Formula Supply VDC 8 VDC 0 020 A 15 to 300 psig 3x FS 500 psis 3x FS 0 to 95 RH non condensing Any gas or liquid compatible with 304L Stainless Steel 150 lbs in 16 95 Nm SENSOR NON SPECIFIC INFORMATION Supple Voltage Supply Current Output Signal Accuracy1 22 C 71 6 F Thermal Error 40 to 105 C Stability 250 Hours 225 F 125 C Operating Storage Temperature Ranges Process ...

Отзывы: