DSIM-SS

 

Installation Guide Rev B

 

Page 7 of 18

 

 

 

® 

 

 

 

DSIM Mode Flow Chart 

 

 

MGC mode: 

This is the default mode for Amp. Setup 

 

 

The controller LED will be solid blue 

The DSIM LED will blink blue every half sec 

 

Press 

MODE 

once to start the 

align process 

 

 

Align Process: 

 

This takes 45 sec. to lock on to the pilot CH., 

and save the pilot level 

The controller will flash blue/ red 

The DSIM will flash CH & type pattern 

 
 

 

DSIM Locks on to the 

channel successfully, it 

starts the AGC mode 

AGC mode: 

The DSIM will maintain pilot level stability 

 

 

The controller will blink blue every half sec. 

The DSIM LED will give a channel & 

ch type pattern 

 

If the pilot is too 

low, the DSIM 

will use the 

TGC process 

If the pilot drop 

more than 10 

dB the DSIM 

will go to 

thermal fallback 

 

 

Align Process: Thermal Fallback 

If the Align Process fails check/ adjust levels or 
reduce AGC PAD. return the MGC mode to try 
again. 

DO NOT 

leave the DSIM in this mode. 

The controller will flash blue/ red 

The DSIM will flash blue/ orange 

AGC mode: Thermal Fallback 

The DSIM will calculate the output level until the 

pilot channel returns. Then the DSIM will resume 

AGC mode. 

The controller will blink blue every half sec 

The DSIM will flash blue/ orange 

 

 

 
 
 
 

Press 

MODE 

once to return to MGC mode 

TGC mode: 

This mode calculates the output level based on 

the internal Amp. Temperature 

The controller LED will be solid purple 

The DSIM LED will give the cable length 

(9, 18, 27) dB and three long blinks 

 
 

 

Press 

MODE 

once from any 

of these 4 

modes to go to 

TGC mode 

Содержание DSIM-SS

Страница 1: ...DSIM SS Installation Guide Revision B...

Страница 2: ...stage slope 3 Check and set desired amplifier levels 4 Re install the RF module faceplate 5 Plug the controller cable into the DSIM and plug the controller into the cable 6 Press mode button once The...

Страница 3: ...TATION 2 2 DSIM AGC MODULE DSIM CONTROLLER OVERVIEW 4 3 DSIM MODE DEFINITIONS 6 4 DSIM CONTROLLER OPERATION INSTRUCTION GUIDELINES 8 5 DSIM CONTROLLER STATUS LED ESSENTIALS 8 6 DSIM MODULE STATUS LED...

Страница 4: ...gital or to change the operational mode into the SPAGC thermal AGC or manual modes of operation Having this flexibility to reprogram the DSIM modules is a huge cost savings when doing system modificat...

Страница 5: ...the different operational modes and settings of the DSIM during setup and operation The DSIM controller is used to set the DSIM module s pilot channel and to change into the different operational mode...

Страница 6: ...DSIM will make gain adjustments based on the changes in the internal temperature of the station In the TGC mode there is a selection of 9 18 or 27 dB for the amount of cable that is in front of the st...

Страница 7: ...SIM will use the TGC process If the pilot drop more than 10 dB the DSIM will go to thermal fallback Align Process Thermal Fallback If the Align Process fails check adjust levels or reduce AGC PAD retu...

Страница 8: ...to Align Mode to load controller channel setting DSIM module will then automatically switch to AGC mode In AGC Mode Click to return to TGC Mode In TGC Mode Click to go to MGC Mode Note 1 Making adjust...

Страница 9: ...able in front of the amplifier Quick Blue Orange Blinks Pilot paste in progress Wait or Pilot channel not found or lost LED Fault Conditions Blinking Patterns LED Blinking Pattern Indications Steady o...

Страница 10: ...is for large increments Below 0 F 2dB Between 40 F 0 F 1dB Between 40 F 80 F no change Between 80 F 100 F 1dB Above 100 F 2dB 4 If the DSIM SS has a slope POT use it to set the inter stage slope 5 Ch...

Страница 11: ...to blinking blue and instead DSIM LED flashes blue and orange the pilot signal is either too high or too low going into the DSIM Check the output signal to verify that you have the correct output leve...

Страница 12: ...ller LED stops flashing the red blue sequence it should then display a constant blue indicating that it is in MGC manual mode Click Mode button twice to go from MGC to TGC The LED on the controller sh...

Страница 13: ...ashes Blue Operation Orange Programming 18 dB 1 Dit 8 Dits 27 dB 2 Dits 7 Dits 9 Set the level and slope of the amplifier to the design specifications with the inputpad and Equalizer NOTE The station...

Страница 14: ...00 5 Dits 7 Dits 58 427 25 426 021 429 00 5 Dits 8 Dits 59 433 25 432 022 435 00 5 Dits 9 Dits 60 439 25 438 022 441 00 6 Dits 1 Dash 61 445 25 444 022 447 00 6 Dits 1 Dits 62 451 25 450 023 453 00 6...

Страница 15: ...5 558 028 561 00 8 Dits 1 Dash 81 565 25 564 028 567 00 8 Dits 1 Dits 82 571 25 570 029 573 00 8 Dits 2 Dits 83 577 25 576 029 579 00 8 Dits 3 Dits 84 583 25 582 029 585 00 8 Dits 4 Dits 85 589 25 588...

Страница 16: ...ts 108 697 25 696 035 699 00 1 Dits 1 Dash 8 Dits 109 703 25 702 035 705 00 1 Dits 1 Dash 9 Dits 110 709 25 708 035 711 00 1 Dits 1 Dits 1 Dash 111 715 25 714 036 717 00 1 Dits 1 Dits 1 Dits 112 721 2...

Страница 17: ...3 Dits 1 Dash 131 835 25 834 042 837 00 1 Dits 3 Dits 1 Dits 132 841 25 840 042 843 00 1 Dits 3 Dits 2 Dits 133 847 25 846 042 849 00 1 Dits 3 Dits 3 Dits 134 853 25 852 043 855 00 1 Dits 3 Dits 4 Dit...

Страница 18: ...munications Inc 23307 66th Avenue South Kent WA 98032 Rev B 04 08 2021 Printed in U S A ACI Communications Inc reserves the right to discontinue the manufacture or change specifications without prior...

Отзывы: