4. DSIM Controller Operation Instruction Guidelines
Switch
Function
Description
+
Increase
In MGC Gain Mode, Click to increase the inter-stage RF
level.
MGC - Slope Mode, Click to increase inter-stage slope
In AGC Mode, no function
In TGC Mode, Click to increase cable length value
-
Decrease
In MGC Mode, Click to decrease the inter-stage RF level
In MGC Slope Mode, Click to decrease the inter-stage slope.
In AGC Mode, no function
In TGC Mode, Click to decrease cable length value
Mode
Mode Change
In MGC mode, Click to go to Align Mode to load controller
channel setting, DSIM
module will then automatically switch
to AGC mode
In AGC Mode, Click to return to TGC Mode
In TGC Mode, Click to go to MGC Mode