A
CHI
®
18
3/
Please check Rework station surrounding environment, as far as possible away from
the air outlet and other sources.
4/
Do not open upper fan in the welding process,
5/
Just remember that:
The max tempertature of lead rework is approximately 183
,
!
!
!
Reflow temp:185
"
"
"
190
,
Reflow time: 10 Sec
#
#
#
that of lead free is approximately 217
.
!
!
!
Reflow temp:220
"
"
"
225
Reflow time: 15 Sec
#
#
#
6/
No matter you click "Run" in the IRSOFT or Push the “start switch” on the control
board
Rework station will be autorun current program segment in the
Temperature Controller!
So you must Select the appropriate temperature program segment in the
“PTN ”windows, or You can downloaded IRSOFT’data to the controller, covered,
then run.