Chapter 4
83
Undetermined Problems
The diagnostic problems does not identify which devices fail, which devices are incorrectly installed, whether a
short circuit happens, or whether the system is inoperative.
Note:
Verify if all devices attached are supported by the computer.
Note:
Verify if the power supply used at the time of failure is operating correctly. You can refer to “Power
System Check”.
Follow the procedures below to isolate the failing FRU. Do not isolate non-defective FRU.
1. Power off the computer.
2. Visually check the devices. If any problems are found, replace the FRU.
3. Remove or disconnect all of the following devices:
•
Non-Acer devices
•
Printer, mouse, and other external devices
•
Battery Pack
•
Hard disk drive
•
DIMM
•
CD-ROM / Diskette drive module
•
PC cards
4. Power on the computer.
5. Determine if the problem has been resolved.
6. If the problem does not recur, reconnect the removed devices one at a time until you find the failed FRU.
7. If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU.
•
System board
•
LCD assembly
Содержание TravelMate 8210
Страница 10: ...XI TOC Parts 91...
Страница 13: ...Chapter 1 3 Weight and Dimensions 3 kg 6 6 lbs 364 W x 271 D x 26 3 38 H mm 14 33 x 10 66 x 1 03 1 49 inches...
Страница 29: ...Chapter 1 19...
Страница 94: ...Chapter 5 84 Top View of Main Board Jumper and Connector Locations Chapter 5...
Страница 95: ...85 Chapter 5 Part One of Top View Part Two of Top View...
Страница 97: ...87 Chapter 5 Bottom View Part One of Bottom View...
Страница 100: ...90 Chapter 6 Exploded Diagram...