Troubleshooting
Indicator-Related Symptoms
Symptom / Error
Action in Sequence
Indicator incorrectly remains
off or on, but system runs
correctly
Reconnect the inverter board
Inverter board
System board
Power-Related Symptoms
Symptom / Error
Action in Sequence
Power shuts down during
operation
Power source (battery pack and power adapter).
See “Power System Check” on page 88.
Battery pack
Power adapter
Hard drive & battery connection board
System board
The system doesn’t power-
on.
Power source (battery pack and power adapter).
See “Power System Check” on page 88.
Battery pack
Power adapter
Hard drive & battery connection board
System board
The system doesn’t power-
off.
Power source (battery pack and power adapter).
See “Power System Check” on page 88.
Hold and press the power switch for more than 4
seconds.
System board
Battery can’t be charged
See “Check the Battery Pack” on page 88.
Battery pack
System board
PCMCIA-Related Symptoms
Symptom / Error
Action in Sequence
System cannot detect the
PC Card (PCMCIA)
PCMCIA slot assembly
System board
PCMCIA slot pin is
damaged.
PCMCIA slot assembly