P5270/P5270 Refresh
5-8
Confidential
No
Step
Procedure
Photo
9
1. When Firmware
Upgrade Process is
finished, the LED
power light on.
2. Unplug USB Cable
and Power Cord.
Re-plug in Power
Cable.
10
Check
Firm
-
ware
Restart the unit and enter
the Service Mode.Then
choose”Information
and Reset” item to check
the Firmware
Version.
(For entering Service
Mode, please refer to
Chapter 4 Function Test
and Alignment Procedure.)
5-5 Waveform Download
1.Plug in power cord and hold on “Up” button,then press the “Power” button
Note: After about 5s, Power LED turns blue while Temp LED flashes in red for about 2s,
then release the “Up”button.
2.
After that, please check the LED status and judge the actions as the following table:
LED Status
Result
Power(blue)+TEMP(red)+LAMP(red)
OK
Power(blue)+TEMP(red)
Fail
Note: this step must be excuted after FW, Main Board and Lamper Driver changed!
Содержание P5270 - XGA DLP Projector
Страница 22: ...1 17 P5270 P5270 Refresh Confidential Remote Control Layout ...
Страница 25: ...1 20 P5270 P5270 Refresh Confidential Note ...
Страница 26: ...1 21 P5270 P5270 Refresh Confidential Getting Started ...
Страница 28: ...1 23 P5270 P5270 Refresh Confidential System Block Diagram ...
Страница 29: ...1 24 P5270 P5270 Refresh Confidential Bottom Cover Dimension ...
Страница 45: ...2 16 P5270 P5270 Refresh Confidential No Procedure Photo 2 Disassemble LVPS Module LVPS Module ...
Страница 59: ...2 30 P5270 P5270 Refresh Confidential No Procedure Photo 3 The disassembly is complet ed Bottom Cover ...
Страница 95: ...7 1 P5270 P5270 Refresh Appendix A Exploded Overview D C P5270 Confidential ...
Страница 107: ...7 13 Confidential P5270 P5270 Refresh BOTTOM HOUSING MODULE ...