4-7
Confidential
P5270/P5270 Refresh
No
Step
Specification
Procedure
Photo
8
R, G, B
and White
Color Per
-
formance
Each R, G, B
color should be
normal without
color abnormal
issue
- Test Pattern: R, G, B and
White Color
9
Dead Pixel
(Bright
pixel)
Cannot accept
any bright pixel
- Test Pattern : Full Black
Dead
Pixel (Dark
pixel)
The numbers
of dead pixel
should be small
-
er or amount to
6 pixel.
- Test Pattern : Full White
10
Blemish
(Bright)
The bright blem
-
ish cannot be
accepted if the
problem appear
with Gary 30
patterns
- Test Pattern : Full Black /
Gray 30
Содержание P5270 - XGA DLP Projector
Страница 22: ...1 17 P5270 P5270 Refresh Confidential Remote Control Layout ...
Страница 25: ...1 20 P5270 P5270 Refresh Confidential Note ...
Страница 26: ...1 21 P5270 P5270 Refresh Confidential Getting Started ...
Страница 28: ...1 23 P5270 P5270 Refresh Confidential System Block Diagram ...
Страница 29: ...1 24 P5270 P5270 Refresh Confidential Bottom Cover Dimension ...
Страница 45: ...2 16 P5270 P5270 Refresh Confidential No Procedure Photo 2 Disassemble LVPS Module LVPS Module ...
Страница 59: ...2 30 P5270 P5270 Refresh Confidential No Procedure Photo 3 The disassembly is complet ed Bottom Cover ...
Страница 95: ...7 1 P5270 P5270 Refresh Appendix A Exploded Overview D C P5270 Confidential ...
Страница 107: ...7 13 Confidential P5270 P5270 Refresh BOTTOM HOUSING MODULE ...